2.5.5
Overview of the EVSE, inside (UL model)
A
B
C
D
F
E
G
H
A
Maintenance cover
B
Primary Ethernet connection
C
Socket for a Nano-M2M SIM card
D
Secondary Ethernet connection
E
Smart meter connection
F
Terminal block for dry contacts
input and output
G
Terminal block for the AC input
H
Terminal block for the EV charge
cable or the socket
Part
Function
Maintenance cover
To prevent access to the electrical components of the
EVSE
Primary Ethernet connec-
tion
To connect the Ethernet cable
Socket for a Nano-M2M
SIM card
To connect the EVSE to the internet 4G
Secondary Ethernet con-
nection
To use one Ethernet cable connection for multiple EV-
SEs. There is no communication between the EVSEs.
Smart meter connection
To connect the cables for Modbus RTU - RS485
Terminal block for dry con-
tacts input and output
Not used
Terminal block for the AC
input
To connect the AC input cable from the grid
Terminal block for the EV
charge cable or the socket
To connect the EV charge cable or the socket outlet
Description
BCM.V3Y00.0-EN | 002
17
Содержание Terra AC
Страница 1: ...User manual Terra AC Copyright ABB All rights reserved ...
Страница 54: ......