Parameter
Specification
[mm]
[in]
Z1
> 200
> 8
Z2 (indoor use)
450 to 1200
18 to 48
Z2 (outdoor use)
600 to 1200
24 to 48
7.7
AC input specifications
7.7.1
General specifications
Parameter
Specification
Earthing systems
IT
TT
TN-S
TN-C-S
Frequency
50 Hz or 60 Hz
Overvoltage category
Category III
Protection
Overcurrent
Overvoltage
Undervoltage
Earth fault, including DC leakage protec-
tion
3
Integrated surge protection
7.7.2
AC input specifications (IEC portfolio)
Parameter
Specification
Input AC power connection
1 phase or 3 phase
Input voltage (1 phase)
230 V AC
Input voltage (3 phase)
400 V AC
Standby power consumption
4.6 W
Earth (ground) fault protection
30mA AC, 6 mA DC
Maximum input power (1 phase)
3.7 kW (16 A)
7.4 kW (32 A)
Maximum input power (3 phase)
11 kW (16 A)
22 kW (32 A)
0.25-5 (32) A for MID certified models
3
Only for EVSEs in the IEC portfolio
Technical data