5
Maintenance and cleaning
5.1
Maintenance schedule
Task
Frequency
Procedure
Clean the cabinet cover
and the enclosure of the
EVSE.
4 months
Do a visual check for dam-
age on the cabinet.
Before each use
Do a visual check for dam-
age on the EV charge ca-
bles or outlet and the con-
nectors.
Before each use
5.2
Clean the cabinet
Preliminary requirements
•
Cleaning agent. Refer to section
•
Non-abrasive tool. Refer to section
.
Danger:
Hazardous voltage
•
Do not apply high-pressure water jets. Water can leak into the
cabinet.
Note: When the EVSE is put in a corrosion sensitive environment,
superficial rust is possible on welding points. This rust is only visual.
There is no risk for the integrity of the cabinet. The procedure below
removes the rust.
Procedure
1. Rinse with low-pressure tap water to remove rough dirt.
2. Apply a a solution of cleaning agent to the cabinet and let it soak.
3. Manually remove dirt. Use the non-abrasive tool.
Caution: Do not use abrasive tools.
4. Rinse with low-pressure tap water.
5. If necessary, apply wax on the front for extra protection and gloss.
6. If there was rust and you want it not to appear again, apply a rust-preventive
primer. Ask the manufacturer for specifications and instructions.