background image

12

SCR E E N M A STE R RVG 20 0 / PA PE R LE SS R ECOR DE R

  |  C I/R VG 2 0 0/0 01- EN R E V. A

5

  Menus overview

…Configuration level menus

I/O

Analog I/P

Input

Input adjust 
Operator Calibrate 
Sensor Calibration

Relay

Relay F1

Source 
Polarity

Ethernet

Ethernet

DHCP 
IP Address

FTP

FTP user 1 (4)

Modbus TCP
email

Auto Address 
Sender Address

Email 1(2)

SMTP Server IP address 

Recipient 1, 2, 3

 

Options enabled 

Trigger 1-5

 

Trigger 6-10

Modbus TCP

Implementation – Slave 
Modbus TCP Port 
Reverse IEEE Data
Implementation – Master 
Modbus TCP Port 
Poll Rate 
Poll fail limit 
Response Timeout

Client Authorization TCP

TCP Client Access 

Authorized IP 1 – 6

Comms analog I/P

Comms analog I/P 
Protocol

Comms Digital I/P

Comms Digital I/P 
Protocol

   

Functions

Linearizer

Adjust custom linearizer1 (2)

RTA 1 (4)

Alarm tag  
Daily enables 

1st of the month enable 

 

On time  
Duration  
Log enable

   

Logic Editor

LE  1 (24)

Operand / Operator 1 (6) 

 

Eqtn tag & log enable

   

Maths equations

Maths  1 (24)

Block Type  
Equation  
Reset source  
Engineering range  
Tag  
Fault detect level  
Fault Detect Direction

Содержание ScreenMaster RVG200

Страница 1: ...s and fuse requirements 4 Navigation navigating the user interface quickly and effectively 5 Menus overview menu familiarization 6 Basic setup steps required for first time use 7 Symbols and icons a s...

Страница 2: ...easurement Control and Laboratory Use and complies with US NEC 500 NIST and OSHA Safety conventions WARNING In this manual a warning is used to indicate a condition which if not met could cause seriou...

Страница 3: ...ted to the installation of firewalls application of authentication measures encryption of data installation of anti virus programs etc to protect the product the network its system and the interface a...

Страница 4: ...0 RVG200 RVG200 RVG200 Ambient temperature 50 C 122 F Max 0 C 32 F Min Eye level location Humidity 5 to 95 Avoid vibration Figure 1 Locating the recorder 2 Panel mounting the recorder Referring to Fig...

Страница 5: ...rm to either IEC 60227 or IEC 60245 The terminals accept cables from 0 8 to 2 5 mm2 18 to 14 AWG The recorder conforms to Installation Category II of IEC 61010 All connections to secondary circuits mu...

Страница 6: ...igure 4 1 Make connections to the power supply terminals module position E as follows AC supply terminals 1 line 2 neutral 3 ground or DC supply terminals 4 5 IMPORTANT NOTE Tighten terminal screws to...

Страница 7: ...old junction assembly fitted Inputs 1 to 6 RTD R THC Volt free digital input mV V ma digital input V A B C D Analog Input A B C D Relay C D Hybrid E Power supply RJ45 USB 100 to 240 V AC 24 V DC Input...

Страница 8: ...lay Operator menu icons page 2 of 2 Exit Operator menus return to previous view Display associated menus Access dialog Accept settings Exit display Figure 7 Navigating menus Navigating groups and view...

Страница 9: ...or Log view Recorder functions are accessed by pressing the icon associated with the required function Select Group Operator Message Screen Capture Auto Group Scroll Trace Select Start Batch Select Vi...

Страница 10: ...nal storage media c Create a new configuration based on the instrument s default configuration System Configuration Common Functions Groups Logic Editor Channels Maths equations I O Configuration menu...

Страница 11: ...Points Menu enables Bar Bar graph view enable Bar graph markers Menu enables Batch if option enabled Enable Batch Recording Start Stop Abort Operator Login Batch Number Field 1 3 Title Channels Setup...

Страница 12: ...P Implementation Slave Modbus TCP Port Reverse IEEE Data Implementation Master Modbus TCP Port Poll Rate Poll fail limit Response Timeout Client Authorization TCP TCP Client Access Authorized IP 1 6 C...

Страница 13: ...rn to the Common Configuration level Time menu options Setup Groups and Channel allocation 1 Press the Setup tab and at the Number of Groups field press and enter the number of Groups required Press t...

Страница 14: ...O page displaying fitted I O modules IMPORTANT NOTE I O modules are detected automatically 2 Press the icon associated with the required module to display the dialog and fields associated with that m...

Страница 15: ...Active Alarm event icons Totalizer icons Audit log icons High process alarm Low process alarm Delayed high process alarm Delayed low process alarm High latch alarm Low latch alarm Fast rate alarm Slow...

Страница 16: ...right to make technical changes or modify the contents of this document without prior notice With regard to purchase orders the agreed particulars shall prevail ABB does not accept any responsibility...