Table 198. Impedance functions, alternatives
Function
Function
identification
Ordering no
Position
Available
qty
Selected
qty
Notes and rules
Note: One and only one of alternatives 1 to 6 must be selected. *) Selected qty = 0 for functions in unselected alternatives.
Alternative 1 Distance protection, quadrilateral
Distance protection zone, quadrilateral characteristic
ZMQPDIS,
ZMQAPDIS
1MRK005907-AA
1
1-5 *)
Directional impedance quadrilateral
ZDRDIR
1MRK005907-BA
2
1-2 *)
Phase selection, quadrilateral characteristic with fixed angle
FDPSPDIS
1MRK005907-CA
3
2 *)
Alternative 2 Distance protection for series compensated lines, quadrilateral
Phase selection, quadrilateral characteristic with fixed angle
FDPSPDIS
1MRK005907-CA
3
2 *)
Distance measuring zone, quadrilateral characteristic for series
compensated lines
ZMCPDIS,
ZMCAPDIS
1MRK005907-DA
4
1-6 *)
Directional impedance quadrilateral, including series
compensation
ZDSRDIR
1MRK005907-EA
5
1-2 *)
Alternative 3 Distance protection, mho (mho for phase - phase fault and mho in parallel with quad for earth fault)
Full-scheme distance protection, mho characteristic
ZMHPDIS
1MRK005907-FA
6
1-5 *)
Full-scheme distance protection, quadrilateral for earth faults
ZMMPDIS,
ZMMAPDIS
1MRK005907-GA
7
1-5 *)
Directional impedance element for mho characteristic
ZDMRDIR
1MRK005907-HA
8
1-2 *)
Additional distance protection directional function for earth faults ZDARDIR
1MRK005907-KA
9
1-2 *)
Mho impedance supervision logic
ZSMGAPC
1MRK005907-LB
10
1 *)
Faulty phase identification with load encroachment
FMPSPDIS
1MRK005907-MA
11
2 *)
Alternative 4 Distance protection, quadrilateral with separate settings for PP and PE
Directional impedance quadrilateral
ZDRDIR
1MRK005907-BA
2
1-2 *)
Distance measuring zone, quad characteristic separate Ph-Ph
and Ph-E settings
ZMRPDIS,
ZMRAPDIS
1MRK005907-NA
12
1-5 *)
Phase selection, quadrilateral characteristic with settable angle
FRPSPDIS
1MRK005907-PA
13
2 *)
Alternative 5 High speed distance protection, quadrilateral and mho
High speed distance protection, quad and mho characteristic
ZMFPDIS
1MRK005907-SC
14
1-2 *)
Alternative 6 High speed distance protection for series compensated lines, quadrilateral and mho
High speed distance protection for series comp. lines, quad and
mho characteristic
ZMFCPDIS
1MRK005907-RC
15
1-2 *)
Optional with alternative 1
Directional impedance element for mho characteristic
ZDMRDIR
1MRK005907-HA
8
0-2
Optional with alternative 3
Phase selection, quadrilateral characteristic with fixed angle
FDPSPDIS
1MRK005907-CA
3
0-2
Optional with alternatives 1, 2 and 4
Additional distance protection directional function for earth faults ZDARDIR
1MRK005907-KA
9
0-2
Faulty phase identification with load encroachment
FMPSPDIS
1MRK005907-MA
11
0-2
Optional with alternatives 1, 2, 3 and 4
Phase preference logic
PPLPHIZ
1MRK005908-DB
16
0-1
Optional with alternative 5 and 6
Phase preference logic
PPL2PHIZ
1MRK005908-DC
17
0-1
Optional with any alternative
Power swing detection
ZMRPSB
1MRK005907-UA
18
0-1
Automatic switch onto fault logic, voltage and current based
ZCVPSOF
1MRK005908-AA
19
1
Power swing logic
PSLPSCH
1MRK005907-VA
20
0-1
PoleSlip/Out-of-step protection
PSPPPAM
1MRK005908-CB
21
0-2
Out-of-step protection
OOSPPAM
1MRK005908-GA
22
0-1
Table 199. Current protection
Position
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
C
00
0
00
1
0
0
0
0
0
1MRK 506 372-BEN -
Line distance protection REL670 2.2
Product version: 2.2
ABB