Table 226. Analog system selection
Analog system
Ordering no
Selection
Notes and rules
When more than one TRM is selected, the connector type on both TRMs must be the same (A compression or B ring lug).
Slot position (front view/rear view)
P40/X401
P41/X411
No Transformer input module included
X0
X0
Only valid if IEC 61850-9-2
Process bus communication is
selected.
TRM 9I 1A + 3U 110/220V, 50/60Hz, compression terminals
1MRK002247-BG
A3
A3
TRM 9I 5A + 3U 110/220V, 50/60Hz, compression terminals
1MRK002247-BH
A4
A4
TRM 5I 1A + 4I 5A + 3U 110/220V, 50/60Hz, compression terminals
1MRK002247-BK
A5
A5
TRM 6I 1A + 6U 110/220V, 50/60Hz, compression terminals
1MRK002247-AG
A6
A6
TRM 6I 5A + 6U 110/220V, 50/60Hz, compression terminals
1MRK002247-AH
A7
A7
TRM 6I 1A, 50/60Hz, compression terminals
1MRK002247-DG
A8
TRM 6I 5A, 50/60Hz, compression terminals
1MRK002247-DH
A9
TRM 7I 1A + 5U 110/220V, 50/60Hz, compression terminals
1MRK002247-AP
A12
A12
TRM 7I 5A + 5U 110/220V, 50/60Hz, compression terminals
1MRK002247-AR
A13
A13
TRM 6I 5A + 1I 1A + 5U 110/220V, 50/60Hz, compression terminals
1MRK002247-AU
A14
A14
TRM 3I 5A + 4I 1A + 5U 110/220V, 50/60Hz, compression terminals
1MRK002247-AV
A15
A15
TRM 3I 5A + 3I 1A + 6U 110/220V, 50/60Hz, compression terminals
1MRK002247-AE
A16
A16
TRM 3IM 1A + 4IP 1A + 5U 110/220V, 50/60Hz, compression terminals
1MRK002247-EA
A17
A17
TRM 3IM 5A + 4IP 5A + 5U 110/220V, 50/60Hz, compression terminals
1MRK002247-EB
A18
A18
TRM 9I 1A + 3U 110/220V, 50/60Hz, ring lug terminals
1MRK002247-BC
B3
B3
TRM 9I 5A + 3U 110/220V, 50/60Hz, ring lug terminals
1MRK002247-BD
B4
B4
TRM 5I 1A + 4I 5A + 3U 110/220V, 50/60Hz, ring lug terminals
1MRK002247-BF
B5
B5
TRM 6I 1A + 6U 110/220V, 50/60Hz, ring lug terminals
1MRK002247-AC
B6
B6
TRM 6I 5A + 6U 110/220V, 50/60Hz, ring lug terminals
1MRK002247-AD
B7
B7
TRM 6I 1A, 50/60Hz, ring lug terminals
1MRK002247-DC
B8
TRM 6I 5A, 50/60Hz, ring lug terminals
1MRK002247-DD
B9
TRM 7I 1A + 5U 110/220V, 50/60Hz, ring lug terminals
1MRK002247-AS
B12
B12
TRM 7I 5A + 5U 110/220V, 50/60Hz, ring lug terminals
1MRK002247-AT
B13
B13
TRM 6I 5A + 1I 1A + 5U 110/220V, 50/60Hz, ring lug terminals
1MRK002247-AX
B14
B14
TRM 3I 5A + 4I 1A + 5U 110/220V, 50/60Hz, ring lug terminals
1MRK002247-AY
B15
B15
TRM 3I 5A + 3I 1A + 6U 110/220V, 50/60Hz, ring lug terminals
1MRK002247-AF
B16
B16
TRM 3IM 1A + 4IP 1A + 5U 110/220V, 50/60Hz, ring lug terminals
1MRK002247-EC
B17
B17
TRM 3IM 5A + 4IP 5A + 5U 110/220V, 50/60Hz, ring lug terminals
1MRK002247-ED
B18
B18
Selected
Table 227. Maximum quantity of I/O modules, with compression terminals
When ordering I/O modules, observe the maximum quantities according to the tables below.
Note: Standard order of location for I/O modules is BIM-BOM-SOM-IOM-MIM from left to right as seen from the rear side of the IED, but can
also be freely placed.
Note: The maximum quantity of I/O modules depends on the type of connection terminals.
Case sizes
BIM
IOM BOM/
SOM
MIM Maximum in case
1/1 x 19” rack casing,
one (1) TRM
14
6
4
4
14 *)
1/1 x 19” rack casing,
two (2) TRM
11
6
4
4
11 *)
3/4 x 19” rack casing,
one (1) TRM
8
6
4
4
8 *)
3/4 x 19” rack casing,
two (2) TRM
5
5
4
4
5 *)
1/2 x 19” rack casing,
one (1) TRM
3
3
3
1
3
*) including a combination of maximum four modules of type BOM, SOM and MIM
1MRK 506 372-BEN -
Line distance protection REL670 2.2
Product version: 2.2