Communication
36
The format of the input assembly is:
USER TRANSPARENT assembly
USER TRANSPARENT assembly allows the use of the ABB
Drives communication profile. The format of the output assembly
is:
The format of the input assembly is:
Instance 71 (Input assembly)
Byte Bit 7
Bit 6 Bit 5 Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
At
Refer-
ence
Ref
From
Net
Ctrl
From
Net
Ready Running
Reverse
Running
Forward
Warn-
ing
Faulted
1
Drive State
2
Speed Actual Value (Low Byte) *
3
Speed Actual Value (High Byte) *
* See
BASIC SPEED CONTROL assembly
for information on speed actual
value scaling.
Instance 100 (Output assembly)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Control Word (Low Byte)
1
Control Word (High Byte)
2
Speed Reference (Low Byte) *
3
Speed Reference (High Byte) *
* Refer to Drive User's Manual for scaling.
Instance 101 (Input assembly)
Byte Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Status Word (Low Byte)
1
Status Word (High Byte)
2
Speed Actual Value (Low Byte) *
3
Speed Actual Value (High Byte) *
* Refer to Drive User's Manual for scaling.
Содержание RCNA-01
Страница 1: ...ABB Drives User s Manual ControlNet Adapter Module RCNA 01 ...
Страница 2: ......
Страница 4: ......
Страница 6: ...Safety instructions 6 ...
Страница 9: ...Table of contents 9 Technical data 65 RCNA 01 65 Fieldbus link 66 ...
Страница 10: ...Table of contents 10 ...
Страница 14: ...Introduction 14 ...
Страница 20: ...Mechanical installation 20 ...
Страница 32: ...Programming 32 ...
Страница 60: ...Communication 60 ...
Страница 67: ......