Communication
39
EXTENDED SPEED CONTROL PLUS DRIVE PARAMETERS
assembly
EXTENDED SPEED CONTROL PLUS DRIVE PARAMETERS
assembly allows the use of ControlNet AC/DC Drive Profile with
additional user-mapped parameters. The format of the output
assembly is:
The value of Output I/O 1 to 9 sets the data word or drive
parameter defined by Output I/O Par 1 to 9 respectively. See
chapter
Programming
.
Instance 121 (Output assembly)
Byte Bit 7 Bit 6
Bit 5
Bit 4 Bit 3 Bit 2
Bit 1
Bit 0
0
NetRef NetCtrl
Fault
Reset
Run
Reverse
Run
Forward
1
2
Speed Reference (Low Byte) *
3
Speed Reference (High Byte) *
4
Output I/O 1 (Low Byte)
5
Output I/O 1 (High Byte)
6
Output I/O 2 (Low Byte)
7
Output I/O 2 (High Byte)
8
Output I/O 3 (Low Byte)
9
Output I/O 3 (High Byte)
10
Output I/O 4 (Low Byte)
11
Output I/O 4 (High Byte)
12
Output I/O 5 (Low Byte)
13
Output I/O 5 (High Byte)
14
Output I/O 6 (Low Byte)
15
Output I/O 6 (High Byte)
16
Output I/O 7 (Low Byte)
17
Output I/O 7 (High Byte)
18
Output I/O 8 (Low Byte)
19
Output I/O 8 (High Byte)
20
Output I/O 9 (Low Byte)
21
Output I/O 9 (High Byte)
* See
BASIC SPEED CONTROL assembly
for information on speed
reference scaling.
Содержание RCNA-01
Страница 1: ...ABB Drives User s Manual ControlNet Adapter Module RCNA 01 ...
Страница 2: ......
Страница 4: ......
Страница 6: ...Safety instructions 6 ...
Страница 9: ...Table of contents 9 Technical data 65 RCNA 01 65 Fieldbus link 66 ...
Страница 10: ...Table of contents 10 ...
Страница 14: ...Introduction 14 ...
Страница 20: ...Mechanical installation 20 ...
Страница 32: ...Programming 32 ...
Страница 60: ...Communication 60 ...
Страница 67: ......