Communication
50
Services Supported
Instance 0x01, Attributes
Service Code No.
Service Name
0x05
Reset
0x0E
Get Attribute Single
0x10
Set Attribute Single
ID# Attribute
name
Services Description
Data
type
0x03 Run 1
1)
Get, Set 0 = Stop, 1 = Run
BOOL
0x04 Run 2
2)
Get, Set 0 = Stop, 1 = Run
BOOL
0x05 Net Control
2)
Get, Set 0 = Local Control, 1 = Network Control
BOOL
0x06 State
Get
1 = Start/up, 2 = Not_ready, 3 = Ready,
4 = Enabled, 5 = Stopping, 6 = FaultStop,
7 = Faulted
UINT8
0x07 Running 1
3)
Get
0 = Stopped, 1 = Running
BOOL
0x08 Running 2
4)
Get
0 = Stopped, 1 = Running
BOOL
0x09 Ready
Get
1 = Ready, Enabled or Stopping
0 = Other state
BOOL
0x0A Faulted
Get
0 = Not faulted, 1 = Fault occurred
BOOL
0x0B Warning
Get
0 = No Warnings present, 1 = Warning
BOOL
0x0C FaultRst
Get, Set 0
→
1 Fault Reset
BOOL
0x0D Fault Code
Get
The fault that caused the last transition to
the Faulted state.
UINT16
0x0F CtlFromNet
Get
0 = NetControl disabled
1 = NetControl enabled
BOOL
0x11 Force Fault
Get, Set 0
→
1 Force a fault
BOOL
0x12 Force Status
Get
0 = Not Forced
Non-zero = Forced
BOOL
Содержание RCNA-01
Страница 1: ...ABB Drives User s Manual ControlNet Adapter Module RCNA 01 ...
Страница 2: ......
Страница 4: ......
Страница 6: ...Safety instructions 6 ...
Страница 9: ...Table of contents 9 Technical data 65 RCNA 01 65 Fieldbus link 66 ...
Страница 10: ...Table of contents 10 ...
Страница 14: ...Introduction 14 ...
Страница 20: ...Mechanical installation 20 ...
Страница 32: ...Programming 32 ...
Страница 60: ...Communication 60 ...
Страница 67: ......