31
EN
11. Connection of the communication and
control signals
11.1 Communication and control board references
J9
J10
X2
J2
S2
J4
J1
S1
S3
J3
J6
47
37
41
39
40
42
38
42
46
44
45
Terminal Name Terminal Reference Description
J4
37
ABB RS485 service Ethernet connector (RJ45) (ABB service only)
S2
38
RS485 ABB service 120Ohm termination resistance selector switch
(ABB service only)
S1
39
DRM0 activation switch
S3
40
RS485 line 120Ohm termination resistance selector switch
J2
41
Connection to the multifunction relay (ALARM terminal block)
J1
42
Remote ON/OFF terminal block
J3
43
RS485 line terminal block
J9
44
Ethernet connector 2 (RJ45)
J10
45
Ethernet connector 1 (RJ45)
J6
46
USB connector
X2
47
CR2032 Backup battery
(*) The RS-485 connector (RJ45) (ABB Service only)
(37)
and the signal R1 on the Remote ON/OFF terminal block
(42)
are used to bring
the signals on the external RS-485 Service connector