Operation Manual / Power2 340-H / Low-pressure stage
9 Disassembly and assembly / 9.4 Removing the gas outlet casing and
gas outlet flange
© Copyright 2022 ABB. All rights reserved.
HZTL4053_EN
Rev.F
March 2022
9.4
Removing the gas outlet casing and gas outlet
flange
Fig. 22: Removing the gas outlet casing and gas outlet flange
1. Loop around the gas outlet casing (61001) with lifting gear.
2. Remove screw (61003) with Verbus Ripp® washer (61004) and support (61300).
3. Loosen nuts (51009) and remove with Verbus Ripp® washers (51004).
4. Remove the gas outlet casing (61001).
5. Remove the gasket (61002).
6. Measure radial clearance (R) (see chapter
Measuring radial clearances N and R
)
7. Press off the gas outlet flange (57002) with screws (S) according to the following table.
Press-off screws to be used (strength 8.8)*
6x M10
Table 41: Press-off screws to be used
*not included in the Turbo Systems. scope of delivery.