Influencing parameters
The actual values can deviate considerably from the guideline values, for example, due to the
following influences:
¡
Fuel quality and fuel treatment
¡
Load profile (thermal cycling, also number of starts/stops, emergency shutdowns)
¡
Gas inlet temperature
¡
Frequency and execution of turbine and compressor cleaning
¡
Specification of the low-pressure stage
¡
System-specific operating conditions (combustion quality, exhaust gas composition)
For bearing parts
¡
Lubricating oil quality (oil filtering, oil condition, oil monitoring)
¡
Load profile (speed, pressure conditions, temperature)
¡
Number of starts/stops
¡
Unbalance of the rotor (degree of contamination).