![ABB PST30 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/abb/pst30/pst30_installation-and-maintenance-manual_3390451030.webp)
1L1
2T1
4T2
6T3
B1
B2
B3
3L2
5L3
1
100-2
50V
Stop
Star
t In0
In1
Vc
AC/DC, 50/60 Hz
2 3
4 5
6
7
8
9
10
Vp
Vp
11
K4
12
13
14
Vn
15
16
K5
17
18
19
K6
20
LIST
ED
7F39
IND.
CON
T. EQ
.
1SF
A 894 007
IEC 947-4
-2
Ie: 37-72A
Us: 1
00-25
0V AC/DC
UL
Uc: 10
0-2
50V
AC
/DC
FLA
: 37
-68
A
Ma
de in Swede
n
Ue:
220-2
30
380
-400
500
V
72: AC-53a: 8-
1.6:
In line
18,
5
3
7
45
kW
Ue
208
2
20-2
40
440
-480
V
PTC
Key-P
ad
FE
LDBUSS
CAUTION
Fuse
250A
TYP
OWER ZILOX
Max sh
ort circuit current 65
kA a
t
Wire 1-8
Al C
u 75
C on
ly, 35lb
-in
Overload Capac
ity 1
15% o
f C
ontinu
ous
L
N
Made in Sweden
PTC
Key-Pad
Fieldbus
Made in Sweden
PTC
Key-Pad
Fieldbus
5:3 Connection of communication devices (optional)
5:3.1 Fieldbus communication
The fieldbus communication plug must be connected to the communication interface on the front of the PST,
see Figure 26. Make sure that the plug is in correct position and tighten the screw with 0.8 Nm (7.1 lb in) and
additional 1/4 turn.
For programming and other information, see Chapter 7 “ Settings and configuration” and Chapter 8 “ Field-
bus communication (option)”.
5:3.2 External keypad
An external keypad for door mounting can be connected to the softstarter. A 3-meter cable including both the
serial communication and the power supply to the keypad makes the connection.
The external keypad can also be used for transferring parameters from one softstarter to another during
commissioning (temporarily handheld). Note that NEMA 4/4X cannot be achieved when the keypad is not
mounted.
When thee external keypad is used, both keypads will work in parallel but the softstarter keypad always has
the highest priority if the keys on both units are pressed simultaneously.
5:3.3 Transferring parameters
To transfer (copy) parameters from one softstarter to another, connect the keypad to the chosen softstarter and follow the
sequence below.
5:3.3.1 Uploading parameters
Enter the menu
Transfer par.
Select
To Keypad
and confirm by pressing
Select
. A text
Load to Keypad
will be displayed..
Continue by pressing
Execute
and then
Yes
when the text
Are You Sure
is displayed.
Transfer OK
will now be displayed
if the transmission was successful. Otherwise,
Transfer Not OK
will be displayed.
Chapter 5
Connection
Figure 26: Fieldbus plug
Figure 27: Principle of a fieldbus network with PST softstarters connected
Figure 28: External keypad
1L
1
2T1
4T2
6T3
B1
B2
B3
3L
2
5L
3
1
100-
250V
Stop
Start
In0
In1
Vc
AC/DC, 50/
60 Hz
2 3
4 5
6
7
8
9
10
Vp
Vp
11
K4
12
13
14
Vn
15
16
K5
17
18
19
K6
20
LIS
TED 7F39
IND.
CONT
. EQ
.
1SF
A 8
94 007
IEC 947-
4-2
Ie: 37-72A
Us: 100
-250V AC/D
C
UL
Uc: 100-250V
AC/D
C
FLA: 37-68A
Made in
Sweden
Ue:
220-230 380
-400
500
V
72: AC-5
3a: 8-1.6:
In l
ine 18,5
37
45
kW
Ue
208
220-240 440-
480 V
PTC
Key-Pad
FELD
BUSS
CAUTION
Fuse 25
0A TYPO
WER ZI
LOX
Max shor
t circ
uit current 65kA
at
Wire 1
-8 Al
Cu 75C only
, 35l
b-in
Ov
erload Ca
pacity 1
15%
of Continuous
L
N
Figure 29: Upload
5.8
Low Voltage Products & Systems
1SXU 132 021 M0201
ABB nc. • 888-385-1221 • www.abb-control.com
5