Operation Manual / Power2 850-M / 4.2 High-pressure stage
4 Disassembly and assembly / 4.12 Installing the wall insert
© Copyright 2017 ABB. All rights reserved.
HZTL4063_EN
Revision A
August 2017
Fig. 21: Installing the wall insert 2
Part number
Thread and tightening torque
72002
M12x95
50 Nm
Table 11: Tightening torque (72002)
6. Fit a nut (72004) as a safeguard.
7. Remove bracket (90030).
8. Slide in wall insert (77000) as far as it will go.
9. Detach speed measurement cable from provisional holder and insert cable connector
(86515).
10. Fit three studs (72002) again in upper area and tighten.