6 Calculate
Counts Per Meter
using the read and measured values.
For example:
20200000/1005 = 20099
7 In RobotStudio, click
Configuration
and select topic
Process
and type
Conveyor Ici
.
8 Edit the unit
ICIx
(where x is the number of the conveyor) and update the
value for parameter
Counts Per Meter
.
9 Tap
OK
.
10 Restart the controller.
Related information
Application manual - Conveyor tracking
.
Technical reference manual - System parameters
.
190
Application manual - PickMaster® Twin - PowerPac
3HAC064218-001 Revision: B
© Copyright 2021 ABB. All rights reserved.
4 Working with PickMaster PowerPac
4.3.4.2 Defining the parameter Counts Per Meter (DSQC 2000)
Continued