![ABB Orion 3 Base Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/abb/orion-3-base/orion-3-base_original-instructions-manual_5140029.webp)
2TLC
172289M0201
Rev C
29
www.abb.com/jokabsafety
2018-04-17
Display
Alignment status
Alignment
quality
Output status when
out of alignment
mode
First and last couple are not aligned
Bad
OSSD OFF
Last couple is not aligned
Bad
OSSD OFF
First couple is not aligned
Bad
OSSD OFF
Every couple over the lower light reception
threshold and no couple over the upper
light reception threshold
Good
OSSD ON
Every couple over the lower light reception
threshold and one couple over the upper
light reception threshold
OSSD ON
Every couple over the upper light reception
threshold
OSSD ON
Maximum light reception
Excellent
OSSD ON
1 ) Keep the active unit in a steady position and adjust the passive unit until the yellow LED ( FIRST) turns off.
This condition shows the alignment of the first transmitter/receiver couple.
2 ) Rotate the passive unit, pivoting around the lower optics axis, until the yellow LED ( LAST) turns off.
NB: Make sure that the green LED (
) is on and steady.
3 ) Slightly turn both units both ways to find the limits of the area in which the green LED (
) is steady and
“4” is
displayed (Maximum alignment). Place both units in the centre of this area.
4 ) Fix the two units firmly using brackets.
Check that the green LED (
) on the active unit is on when the beams are not interrupted. Then check that
the red LED (
) turns on when one single beam is interrupted. This check shall be made with the special
cyli
ndrical “Test Piece” having a suitable size for the resolution of the device used (see paragraph
– “Checks after first installation”).
5 ) Switch the device off and on to normal operating mode.
The alignment level is also monitored during normal operating mode and visualized on the display.
Once the AOPD has been aligned and correctly fastened, the signal on the display is useful both to check the
alignment and to show a change in the environmental conditions (presence of dust, light disturbance and so on). The
behaviour is summarized in the next table.