Chapter 5 – Programming
NIBA-01 Installation and Start-up Guide
5-3
Host Configuration
The devices on the remote bus are automatically detected by the host
controller software, and then assigned input and output memory
addresses. The need for further configuration depends on the host
controller software and the application. The configuration data in
Table 5-2 below is valid for the NIBA-01.
Table 5-2 Host controller configuration data for the NIBA-01 module.
Communication Parameter
Value
Device Name/Type
NIBA-01
ID Code
PCP Mode: 243 (F3h)
IO Mode: 3 (03h)
Length Code
4 (04h)
No. of Process Data Bytes In/Out
6/6
No. of Parameter Data Bytes In/Out
2/2
Register Length (bytes)
8
Profile No.
0
Services Supported
All mandatory services,
Get OV, Read, Write
Maximum PDU Length
64 bytes
COMMUNICATION REFERENCE LIST ENTRIES
Max-PDU Sending-High-Prio
0
Max-PDU Sending-Low-Prio
64 bytes
Max-PDU Receiving-High-Prio
0
Max-PDU Receiving-Low-Prio
64 bytes
PMS-Services-Supported
80 30 00 / 00 00 00;
Client / Server