Cable routing for motor power cable GU MTD750
The motor cables for GU MTD750 are possible to turn approximately 45 degrees
outwards, to avoid breaking the cables.
xx1800000601
Limitations
The following limitations apply when installing and fastening cables for the motor
units or gear units to get best performance and durability.
Bending
Make sure that cables are not bent too close to the fastening points or too sharply.
xx1000001397
Fastening point or connector
A
Minimum distance from fastening point to bend is 100mm
B
Minimum bending radius is 100mm
C
Twisting
The minimum length between the fastening points is 900mm if the cable will be
twisted ±180°.
xx1000001398
Fastening points or connectors
A
Minimum length is 900mm
B
Continues on next page
56
Product manual - Motor Units and Gear Units
3HAC040148-001 Revision: K
© Copyright 2011 -2018 ABB. All rights reserved.
3 Installation
3.3 Fastening cables