background image

M ICROG UA R D™ SOLUTION |

  M I C R O G UA R D  |  U M/M I C R O G UA R D - EN R E V. B

31

 . . .5  System Software

Analyzer Level

Refer to GLA131 Series Microportable user manual, document 
#3KXG167001R4601 .

Содержание MicroGuard solution

Страница 1: ... ABB MEASUREMENT ANALY TICS USER MANUAL MicroGuard solution ...

Страница 2: ...Map 11 Security Configuration 11 5 System Software 12 Overview 12 Recommended Security Settings 12 Application Level 12 Application Feature Overview 12 Operational Overview 13 Updating 17 Third Party Software Requirements 20 Screens 21 Analyzer Level 31 6 Using the System 32 Hardware Inspection 32 System Power On 32 Software Startup 32 Google Drive Account Log in 34 Standard Operation 34 Recording...

Страница 3: ...MICROGUARD SOLUTION MICROGUARD UM MICROGUARD EN REV B 3 ...

Страница 4: ... other network as the case may be Operator shall establish and maintain any appropriate measures such as but not limited to the installation of firewalls application of authentication measures encryption of data installation of anti virus programs etc to protect the product the network its system and the interface against any kind of security breaches unauthorized access interference intrusion lea...

Страница 5: ...ed location 2 Introduction Scope This manual describes accessing and using the MicroGuard solution It details the software features as well as how to update latest versions of the mobile application which are referred to as APK files and how to transfer data both from MicroGuard and MobileGuard Figure 1 depicts the MicroGuard in use Nomenclature Reference in manual Description MicroGuard Analytica...

Страница 6: ...k from Explorer Case to carry the GLA131 Microportable analyzer Straps secure the analyzer in place and backpack straps provide ease of use and mobility Wand and Tip an inlet extension of the analyzer Handle to grip and guide the wand with ease Holds the NX6 to allow for real time data monitoring during surveying Figure 2 Nautiz X6 and Handle Figure 4 Backpack Figure 3 Nautiz X6 Hand Held Device F...

Страница 7: ...vary depending on user requirements Features See Figure 6 for NX6 front panel features See Figure 7 for NX6 rear panel features Figure 6 NX6 Components Figure 7 NX6 Front Panel Features Figure 8 7 NX6 Rear Panel Features 3 System Hardware Part Part Number MicroGuard Complete Accessory Kit ACC MICROGUARD Accessory Case SPA MCG CASE Nautiz X6 Hand held Device SPA MCG PHABLET Bluetooth Dongle ACC BT ...

Страница 8: ...ed backpack straps are fully adjustable Waist belt helps to secure the pack Accessory pocket with Velcro flap closure Table 4 Backpack Specifications Parameters Specifications Battery Life 3 8V 8000 mAh 30 4 Wh Drop Shock 26 drops from 1 2 m 4 ft Sand Dust IP67 IEC 60529 Water IP67 IEC 60529 Parameters Specifications Weight 1 36 kg 3 lb Dimensions 30 48 cm 12 in 25 4 cm 10 in 20 32 cm 8 in NOTE Fo...

Страница 9: ...ng it in place with the backpack straps that loop underneath the analyzer s handle There is a second backpack strap that should be clipped around the analyzer for added security 2 Insert the NX6 into the wand by angling it to fit the curved piece at the end of the frame into the end of the tablet NOTE Do not put on the backpack yet 4 Insert the inlet tubing into the analyzer inlet port 3 Press the...

Страница 10: ...ly 7 Take the end of the wand the other end has been attached to the inlet of the analyzer and secure it into the handle with the screw Unscrew the clip at the bottom of the handle to loosen the clip The clip does not have to be unscrewed all the way 8 Once loose insert the wand and screw the clip until the handle sits firmly You are now ready to begin using the MicroGuard mobile application on th...

Страница 11: ... System Ports Bluetooth Data streams from the analyzer to the mobile application via Bluetooth The application requires access to the following TCP port on the intranet 20002 Websocket data stream from analyzer Ensure that this port is not blocked by any firewall software on the intranet or internet ABB Inc bears no responsibility for security vulnerabilities introduced by opening ports beyond tha...

Страница 12: ...pressure temperature or ringdown of the analyzer is out of its normal operating condition Check the analyzer for specific details Analyzer battery charge level status A gray battery indicates the application is waiting for a response from the analyzer for the battery status see Figure 19 IMPORTANT The NX6 is not GMS certified with Verizon It is recommended to use a SIM card from AT T or TMobile be...

Страница 13: ...ing recorded Operational Overview There are two user accounts for the mobile application admin and tech These two users are designed so that the tech users can survey areas using operational settings within the application chosen by the admin user Refer to the User Management Roles and Privileges section for a list of what each user has access to within the application The following is a sequentia...

Страница 14: ...igure 26 Select Record 7 It is recommended to set the following parameters before collecting data Threshold alarm for details refer to the Settings section Aggregation emissions distance for details refer to the Settings section Live gas to display in the time trace for details refer to the Live Gas section Any loaded drive packages for emission regions to investigate for details refer to the Data...

Страница 15: ...t their defaulted values In order to do this with each gas the gas must be toggled 10 When finished collecting data select REC to close the file and generate the PDF report NOTE After selecting REC the analyzer stops streaming data to the hand held device but continues to measure and record data 11 To check the report Select the Menu Data packages Walk Packages see Figure 26 The easiest way is to ...

Страница 16: ...e 30 Red Bluetooth Icon 14 Wait for the Bluetooth icon to turn red This indicates the analyzer is ready to shut down 15 Manually power off the analyzer Refer to the user manual of the analyzer purchased with your system 16 Log out of the application Select Menu Logout then tap the checkmark see Figure 30 For details refer to the Logout section 17 To verify the application is no longer running on t...

Страница 17: ...was not altered by signature or by malware See the release notes for each version s checksum The following process describes how to verify the APK s checksum The update package download will be available to download via ICOS Support Service announcement The package contains the user manual release notes and APK The download link is password protected In order to verify the APK was not altered veri...

Страница 18: ...o pop up for the application then scroll to the bottom to see the current version To install a new apk version uninstall the application via this same window Then follow the steps below for installing the new apk version 3 Select the arrow icon Figure 35 to access the Applications menu Figure 36 Home Screen Figure 38 Connected Devices Figure 39 Select USB Figure 37 Settings Icon 4 Select the Setti...

Страница 19: ...ide panel if it does not automatically display Double click Internal shared storage Figure 40 9 Click the Download folder Figure 41 10 Copy the APK file to this folder Figure 42 11 Once the APK file has been transferred disconnect the NX6 and install the application 12 On the NX6 select the Files application and navigate to the Downloads folder 13 Click ABB MicroGuard current version apk to instal...

Страница 20: ...e application for scanning Select DON T SEND MicroGuard APKs are scanned by three different anti virus applications prior to each release A screen appears indicating the application has installed successfully The ABB MicroGuard application should now appear under all applications Third Party Software Requirements Software upgrades on the NX6 are provided by Handheld For any assistance needed conta...

Страница 21: ...le Changeable Toggle Map follows me Changeable Changeable Toggle Leaks markers Changeable Changeable Comments and markers Add Changeable Changeable Comments and markers Search Changeable Changeable Comments and markers Filter Changeable Changeable Comments and markers Sort Changeable Changeable Comments and markers Display Changeable Changeable Live gas Changeable Changeable Data drive packages Ac...

Страница 22: ...t log in credentials Enabled and can reset others Command Analyzer shutdown Enabled Enabled Logout Enabled Enabled Command Walk Start Enabled Enabled Command Walk Stop Enabled Enabled Saturated Alert Enabled Enabled General Status icon Enabled Enabled Battery icon Enabled Enabled Network icon Enabled Enabled Bluetooth icon Enabled Enabled 5 System Software Application Specific Screens The followin...

Страница 23: ...in the home screen and loaded drive packages In Figure 52 all of the toggles are turned on The selection is highlighted in black and the toggle is in the right enabled position If a toggle is turned off the selection is highlighted in white and the toggle is in the left disabled position Except for the Map follows me icon if a toggle is turned on the icon appears in the map Figure 52 Menu Features...

Страница 24: ...pe of gas and leak amount Figure 54 Comments Markers Figure 56 Comments and Markers Figure 57 Comments and Markers Add Window Figure 55 Leaks Markers Comments and Markers Tap the Menu icon then select Comments and markers to access the Comments and markers menu see Figure 55 During a walk package comments photos and videos can be added to each file When either a drive or walk package is loaded sel...

Страница 25: ... the selection or the X to cancel the selection To delete the line and draw a new one select the trash can icon To undo the last draw select the back arrow icon To save the draw select the checkmark in the upper right corner To exit the drawing feature without saving select the X Filter Tap the Filters icon to limit comments and information to display Check the box next to the type of comments and...

Страница 26: ...con select Live gas then use the adjacent toggle to select the desired gas to view the measured ppm levels of a specific gas Figure 62 shows an example of switching from methane to carbon dioxide Depending on the analyzer type chosen different live gas options will vary Figure 63 Live Gas Selection ...

Страница 27: ...port Icon Tap this icon to pull up the PDF report within the application Square Icon Tap this icon to select the file to be loaded within maps Loaded Packages Lists all files selected to be displayed within maps Select files in this list to remove them from being displayed Figure 65 is an example in which Loaded packages is selected A down arrow means ready for download It indicates that the Googl...

Страница 28: ...his menu admin users can adjust various settings for each walk package Each time a change is made within these tab settings select Confirm to apply the changes In the example in Figure 67 Threshold alarm is selected and settings are specified Refer to Table 5 for Settings screens and the type of access available to admin and tech users The following describes each setting type Threshold alarm gas ...

Страница 29: ...ch color that will display in the walk path in the map during real time and in the generated report Emission aggregation set the distance to group emissions measured above the set threshold value in Threshold alarm Graph and walk line select the walk length and displayed graph timeline length of the time trace graph below the map Google drive log into your google drive account and tap Connect This...

Страница 30: ...u icon scroll down then select Analyzer shutdown 2 When the Do you really want to shutdown the analyzer message appears select the checkmark below the message The Bluetooth icon in the header changes from black to red to indicate the Bluetooth connection is disabled This is the recommended method instead of turning the analyzer power button off Allow for approximately 20 seconds to pass after shut...

Страница 31: ...MICROGUARD SOLUTION MICROGUARD UM MICROGUARD EN REV B 31 5 System Software Analyzer Level Refer to GLA131 Series Microportable user manual document 3KXG167001R4601 ...

Страница 32: ...e frame holds the device Nothing is bent or out of place The screw for the wand operates normally System Power On 1 Power on the Android device 2 Turn on the analyzer Refer to GLA131 Series Microportable user manual document 3KXG167001R4601 Software Startup To start up the MicroGuard application the analyzer and phablet must already be turned on Then perform the following NOTE If at any time durin...

Страница 33: ...ow pair automatically If it does not or if the GLA131 Series Microportable was purchased independent not as part of either the MicroGuard or MicroGuard Lite solutions refer to the MicroGuard Application and Analyzer Bluetooth Pairing section When the application automatically selects the available device you can check the screen to see which analyzer is connected The Bluetooth connection matches t...

Страница 34: ...variety of features has the ability to assist users in locating gas emissions This data displays in the map and the graph below it If any of the described features in the manual do not function as described refer to the troubleshooting portion of the manual and contact Service Recording Icon Tap the data recording icon REC to gather and record data from the analyzer The data will be displayed in r...

Страница 35: ...n appears in the bottom right corner of the screen accompanied by an audio indicator You can tap the speaker icon to mute the alarm but it must be tapped again to enable it for future tests while still logged into the application A red tear drop icon also displays on the map if the measured ppm level crosses the user set threshold level NOTE If Maps was not able to display during the walk package ...

Страница 36: ...torage limit software issues may occur and warning notifications appear in the Data Packages screen Transfer media off the phablet onto your computer MobileGuard Data from the MobileGuard can be viewed within the maps display screen of the MicroGuard application There are three methods to enable viewing Transfer drive files directly from the MobileGuard tablet to the MicroGuard hand held device vi...

Страница 37: ...uld be stored in its pelican case for proper handling see Figure 90 for placement of items Items should not be transported freely where there might be exposure to damage Figure 91 Equipment Storage IMPORTANT Ensure you back up all necessary data before performing a factory reset Perform a factory reset as follows 1 Select the arrow icon Figure 35 to access the Applications menu 2 Select the Settin...

Страница 38: ...how system 4 Find the external storage and media storage applications and clear data for both 5 Restart the device Cannot connect to Google Drive No internet connection User access on your Google account must be managed for an unknown device Connect to a strong internet connection Application crashes An error in the application occurred Close the application restart the device then re launch the a...

Страница 39: ... refer to the GLA131 Series Microportable Analyzer User Manual document 3KXG167001R4601 3 Log into the analyzer software lgr 3456789 See Figure 92 4 Select the Setup Bluetooth Daemon tab see Figure 93 5 Verify that the status for Bluetooth Daemon is running If it does not click the Run button 6 Within 3 minutes click Set Bluetooth visible 7 Open the MicroGuard application 8 Log into the applicatio...

Страница 40: ...bled and packaged in the pelican case as shown and described in Equipment Handling The tubing should be disconnected from the wand to prevent damage of the quick disconnect clips Additionally the filter tip should be stored in such a manner without being bent 8 Appendices Figure 96 Select Bluetooth Device Figure 97 Select Pair Figure 98 Select Confirm 14 A pairing prompt appears in the application...

Страница 41: ...MICROGUARD SOLUTION MICROGUARD UM MICROGUARD EN REV B 41 ...

Страница 42: ...ck of information in this document We reserve all rights in this document and in the subject matter and illustrations contained therein Any reproduction disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB ABB 2021 3KXG167005R4601 ABB Inc Industrial automation 3400 Rue Pierre Ardouin Québec Québec G1P 0B2 Canada Tel 1 800...