Appendix: Safe Torque Off (STO) 205
STO cable
Type
2×2×0.75 m
2
low voltage, single shielded, twisted
pair cable
Maximum length
30 m between STO inputs and the operating
contact
Example cable
Li YCY TP 2×2×0.75 mm
2
shielded twisted pair
cable by HELUKABEL or CEAM
Ambient conditions
Description
Unit
1.6 A model
Operating temperature range
°C
°F
°C
°F
Minimum
Maximum
0
+55*
+32
+122*
0
+55
+32
+131
Storage temperature range
°C
°F
-40 to +85
-40 to +185
All models
Humidity
(maximum, non-condensing)
%
95
Maximum installation altitude
(above m.s.l.)
non-STO parts:
STO function:
m
ft
m
ft
1000. Above 1000 m derate 1.1% / 100 m
3280. Above 3280 ft derate 1.1% / 330 ft
2000
6560
Shock
10 G
Vibration
1 G, 2-200 Hz
* Subject to derating; see page
.