172 Resistor braking
Introduction
Each drive has a
braking capacity
that defines the amount of regenerative energy its
DC bus capacitors can store before the voltage on the capacitors exceeds the drive’s
over-voltage level. In a common DC system, all of the drive’s DC bus capacitors are
connected, so the system braking capacity becomes the sum of all the drives’ braking
capacities. If the total regenerative energy in the system exceeds the system braking
capacity, the excess energy must be diverted into a brake resistor (also known as a
regeneration or ‘regen’ resistor) to be dissipated as heat. The brake resistor can be
connected to one drive in the system, but if that drive’s braking chopper cannot
withstand the total regenerative power in the system, more than one drive must be
fitted with a brake resistor.
System braking capacity
The braking capacity of the drive is calculated from the following formula:
B
dc
= 0.5 x
DC bus capacitance
x (
Brake switching threshold)
2
– (
x
Supply voltage
)
2
2
(
)
where the
Brake switching threshold
is 388 V. This gives the following typical values:
MicroFlex e190
Braking capacity, B
dc
(J)
Model
Frame
DC bus
capacitance (
μ
F)
240 V AC supply
01A6-2
A
560
12.5
03A0-2
A
06A0-2
A
1120
25
09A0-2
A
Содержание MicroFlex e190
Страница 1: ...ABB motion control User s manual MicroFlex e190 servo drive ...
Страница 4: ......
Страница 12: ...12 Table of contents ...
Страница 23: ...Introduction to the manual 23 Related documents See List of related manuals on page 2 inside the front cover ...
Страница 26: ...26 Introduction to the manual ...
Страница 90: ...90 Electrical installation input output ...
Страница 146: ...146 Maintenance ...
Страница 178: ...178 Resistor braking ...
Страница 186: ...186 Accessories ...
Страница 208: ...208 Appendix Safe Torque Off STO ...