3 Maintenance
3.4.7. Replacement of SMB battery
133
3HAC028197-001 Revision: A
©
Co
py
rig
h
t 200
7-
200
8 ABB. All righ
ts reser
v
ed.
3.4.7. Replacement of SMB battery
Location of SMB battery
The SMB battery (SMB = serial measurement board) is located on the left hand side of the
frame as shown in the figure below.
xx0700000029
Required equipment
Removal, battery
The procedure below details how to remove the SMB battery.
A
SMB battery cover
B
SMB battery pack
C
Battery cable
Equipment, etc.
Spare part no.
Note
Battery pack
3HAC16831-1
Battery includes protection circuits. Replace it
only with given spare part no. or an ABB
approved eqvivalent.
Standard toolkit
-
The content is defined in section
Circuit Diagram
3HAC025744-001
See chapter
Circuit diagram
.
Action
Note
1. Move the robot to its calibration position.
This is done in order to facilitate the
updating of the revolution counter.
Continues on next page
Содержание IRB 6660 - 130/3.1
Страница 1: ...Product manual Articulated robot IRB 6660 130 3 1 IRB 6660 205 1 9 M2004 ...
Страница 2: ......
Страница 14: ...How to read the product manual 3HAC028197 001 Revision A 12 Copyright 2007 2008 ABB All rights reserved ...
Страница 310: ...9 Circuit diagram 9 1 Introduction 3HAC028197 001 Revision A 308 Copyright 2007 2008 ABB All rights reserved ...
Страница 332: ... 0 1 23 3 4 5 5 6 2 70 2 888 2 9 6 0 9 9 2 A 8B C D 9 8 B ...
Страница 333: ... 2 3 4 5 5 6 2 70 2 888 2 9 6 0 9 9 1 EF 2 888 2 9 6 9 9 8 B ...
Страница 336: ... 98 2 888 7 066 0 10I 4 5 5 06 6 2 70 2 888 2 9 6 0 9 9 G E 7 F E 7 F 9 8 B ...
Страница 347: ......