Changing the battery
DANGER
Turn off all electric power, hydraulic, and pneumatic pressure supplies to the
robot.
Note
Action
Described in section
Remove the (12pcs) M6 screws hold-
ing the base cover.
1
Remove the base cover.
CAUTION
Clean cover from metal residues be-
fore opening.
Metal residues can cause shortage
on the boards which can result in
hazardous failures.
2
CAUTION
Always cut the paint with a knife and
grind the paint edge when disas-
sembling parts. See
surface on the robot before replacing
parts on page 158
.
Disconnect the battery from the serial
measurement board.
3
Connection (X3).
Note
Used batteries must never be thrown away!
They must be handled as hazardous waste!
Cut the strap and remove the battery
pack.
Use standard tools.
4
Connect the new battery to the serial
measurement board.
5
Connection (X3).
Refit the battery to the SMB, using a
strap.
6
Replace if damaged.
Check the base cover gasket.
7
Described in section
Refit the base cover using the (12pcs)
M6 screws.
8
Described in section
Update the revolution counters.
9
122
Product manual - IRB 360
3HAC030005-001 Revision: Z
© Copyright 2008-2021 ABB. All rights reserved.
3 Maintenance
3.4.1 Changing the battery in the measuring system
Continued