Bracket
E
Attachment screws, 2 pcs
F
Cabling for the signal lamp (included in the robot cabling for axis 6)
G
Required equipment
Note
Spare part no.
Equipment
Includes all components shown in the previ-
ous figure.
3HAC025254-001
Signal lamp
The content is defined in the section
-
Standard toolkit
Installation, signal lamp
The procedure below details how to install the signal lamp on the robot.
Note
Action
DANGER
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
1
Run the cables from inside the upper
arm, as shown in the figure
.
Connect the two cables to the signal lamp.
2
Connectors R3.H1 and R3.H2.
2 pcs; M6x16.
Fit the signal lamp to the upper arm by
securing the
bracket
with two attachment
screws.
3
Shown in the figure
.
Make sure that the lamp is lit when the
controller is in MOTORS ON mode.
4
76
3HAC026048-001 Revision: E
© Copyright 2006-2013 ABB. All rights reserved.
2 Installation and commissioning
2.3.7 Installation of signal lamp (option)
Continued
Содержание IRB 260
Страница 1: ...ABB Robotics Product manual IRB 260 ...
Страница 2: ...Trace back information Workspace R13 1 version a6 Checked in 2013 03 31 Skribenta version 1184 ...
Страница 8: ...This page is intentionally left blank ...
Страница 52: ...This page is intentionally left blank ...
Страница 110: ...This page is intentionally left blank ...
Страница 206: ...This page is intentionally left blank ...
Страница 214: ...This page is intentionally left blank ...
Страница 216: ...This page is intentionally left blank ...
Страница 260: ...This page is intentionally left blank ...
Страница 266: ......
Страница 267: ......