Note
Action
Remove the SMB cover by unscrewing its at-
tachment screws.
4
Pull the battery cable through the hole in the
SMB cover.
Remove the two locknuts and washers from
the
pins
securing the board.
5
All connectors are shown in the figure
Gently disconnect the connectors from the
SMB unit when pulling the board out. Also
disconnect the battery cable from the SMB
unit.
6
All connectors are shown in the figure
Gently connect the connectors to the new
SMB unit and push the board in.
7
Refit the SMB cover using the attachment lock
nuts.
8
Pull the battery cable through the hole in the
SMB cover.
Reassemble the two locknuts and washers to
the pins securing the board.
9
Refit the SMB battery.
10
Always replace a removed gasket with
a new!
Fit a new
gasket
to the cover and refit the
cover with the attachment screws.
11
Art. no. is specified in
Detailed in the section
Update the revolution counters!
12
3HAC026048-001 Revision: E
175
© Copyright 2006-2013 ABB. All rights reserved.
4 Repair
4.6.1 Replacement of SMB unit
Continued
Содержание IRB 260
Страница 1: ...ABB Robotics Product manual IRB 260 ...
Страница 2: ...Trace back information Workspace R13 1 version a6 Checked in 2013 03 31 Skribenta version 1184 ...
Страница 8: ...This page is intentionally left blank ...
Страница 52: ...This page is intentionally left blank ...
Страница 110: ...This page is intentionally left blank ...
Страница 206: ...This page is intentionally left blank ...
Страница 214: ...This page is intentionally left blank ...
Страница 216: ...This page is intentionally left blank ...
Страница 260: ...This page is intentionally left blank ...
Страница 266: ......
Страница 267: ......