Customer cable
3
Air hose
4
Required equipment
Note
Spare part no.
Equipment
3HAC024115-001
Cable unit axis 6
The content is defined in the section
-
Standard toolkit
See the chapter
-
Circuit diagram
Removal, cable unit axis 6
The procedure below details how to remove the cable unit of axis 6 from the robot.
Note/Illustration
Action
In order to facilitate removal of the cable
unit, move the robot to positions:
•
Axis 1: 0º
•
Axis 2: 45º
•
Axis 3 (upper arm): horizontal
•
Axis 6: no significance
1
DANGER
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
2
xx0200000399
Remove the rear cover plate (A) from the
base of the robot by unscrewing the attach-
ment screws (B).
3
Specified in the figure
.
Disconnect the connectors
R1.MP4-6 and
R2.BU4-6
from the base. Also disconnect
the customer cables and the air hose.
4
Disconnect all earth cables.
5
Continues on next page
124
3HAC026048-001 Revision: E
© Copyright 2006-2013 ABB. All rights reserved.
4 Repair
4.3.2 Replacement of cable unit, axis 6
Continued
Содержание IRB 260
Страница 1: ...ABB Robotics Product manual IRB 260 ...
Страница 2: ...Trace back information Workspace R13 1 version a6 Checked in 2013 03 31 Skribenta version 1184 ...
Страница 8: ...This page is intentionally left blank ...
Страница 52: ...This page is intentionally left blank ...
Страница 110: ...This page is intentionally left blank ...
Страница 206: ...This page is intentionally left blank ...
Страница 214: ...This page is intentionally left blank ...
Страница 216: ...This page is intentionally left blank ...
Страница 260: ...This page is intentionally left blank ...
Страница 266: ......
Страница 267: ......