4.6 Frame and base
4.6.1 Replacement of SMB unit
Location of SMB unit
The SMB unit (SMB = serial measurement board) is located on the left hand side
of the base, as shown in the figure below.
A more detailed view of the component and its position may be found in section
Axes 1-3, spare part view 5 on page 252
Note that the robot is shown with the SMB cover already removed!
xx0200000451
Cable, battery/SMB board
A
Battery pack (2-pole battery contact)
B
Serial measurement board
C
Lock nuts
D
Continues on next page
170
3HAC026048-001 Revision: E
© Copyright 2006-2013 ABB. All rights reserved.
4 Repair
4.6.1 Replacement of SMB unit