![ABB IRB 260 Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/abb/irb-260/irb-260_product-manual_5037025.webp)
1.2.3.6 Risks associated with live electric parts
Voltage related risks, general
Work on the electrical equipment of the manipulator must be performed by a
qualified electrician in accordance with electrical regulations.
•
Although troubleshooting may, on occasion, need to be carried out while the
power supply is turned on, the robot must be turned off (by setting the mains
switch to OFF) when repairing faults, disconnecting electric leads and
disconnecting or connecting units.
•
The mains supply to the robot must be connected in such a way that it can
be turned off from outside the robot’s working space.
The necessary protection for the electrical equipment and manipulator system
during construction, commissioning, and maintenance is guaranteed if the valid
regulations are followed.
All work must be performed:
•
by qualified personnel
•
on machine/manipulator system in deadlock
•
in an isolated state, disconnected from power supply, and protected against
reconnection
Voltage related risks, IRC5 controller
A danger of high voltage is associated with, for example, the following parts:
•
Be aware of stored electrical energy (DC link, Ultracapacitor bank unit) in
the controller.
•
Units such as I/O modules, can be supplied with power from an external
source.
•
The mains supply/mains switch
•
The transformers
•
The power unit
•
The control power supply (230 VAC)
•
The rectifier unit (262/400-480 VAC and 400/700 VDC. Note: Capacitors!)
•
The drive unit (400/700 VDC)
•
The drive system power supply (230 VAC)
•
The service outlets (115/230 VAC)
•
The customer power supply (230 VAC)
•
The power supply unit for additional tools, or special power supply units for
the machining process.
•
The external voltage connected to the controller remains live even when the
robot is disconnected from the mains.
•
Additional connections.
Continues on next page
3HAC026048-001 Revision: E
25
© Copyright 2006-2013 ABB. All rights reserved.
1 Safety
1.2.3.6 Risks associated with live electric parts
Содержание IRB 260
Страница 1: ...ABB Robotics Product manual IRB 260 ...
Страница 2: ...Trace back information Workspace R13 1 version a6 Checked in 2013 03 31 Skribenta version 1184 ...
Страница 8: ...This page is intentionally left blank ...
Страница 52: ...This page is intentionally left blank ...
Страница 110: ...This page is intentionally left blank ...
Страница 206: ...This page is intentionally left blank ...
Страница 214: ...This page is intentionally left blank ...
Страница 216: ...This page is intentionally left blank ...
Страница 260: ...This page is intentionally left blank ...
Страница 266: ......
Страница 267: ......