Depending on the installation position, different ambient
operating temperatures are allowed:
Horizontal Installation Position
Ambient operating
temperature (T
A
)
and installation
distance and
position
Maximum num-
ber of fieldbus
channels used
Maximum
fieldbus
voltage
Minimum
distance
Maximum per-
missible ambient
temperature T
A
4
32 V DC
0 mm
55 °C
2
24 V DC
0 mm
60 °C
4
32 V DC
17.5 mm
65 °C
2
24 V DC
17.5 mm
70 °C
The maximum permissible ambient temperature
values are also valid for a 180° rotated
installation position.