Removing the shaft in the front
Note
Action
xx1200001278
Remove the small VK cover.
Note
It is almost impossible to remove the VK
cover without damage. New VK covers are
needed.
1
xx1200001279
•
M16x70 quality steel 8.8-A3F
Unscrew the attachment screw and washer.
2
Dismantle and mounting tool:
3HAC028920-001
xx1200001280
Use the dismantle and mounting tool and
pull out the shaft.
3
Continues on next page
3HAC044266-001 Revision: -
345
© Copyright 2013 ABB. All rights reserved.
4 Repair
4.6.1 Replacing spherical roller bearing, link ear