139
Preventive Maintainance
3ADW000195R0501 DCS800 Service Manual e e
Check the door air filters.
Door filters
Clocked up filters prevent proper cooling of the drive. Wash dirty filters with
water (60°C) and detergent.
Check for dust, corrosion and temperature inside the module / cabinet.
The DCS will run into overtemperature faults if the heatsinks are not clean.
Heatsink
Use compressed air to remove the dust from the heatsinks (the air flow must
be from bottom to top). Fan rotation caused by the compressed air must be
stopped in order to prevent damage.
Use an
ESD vacuum cleaner
to clean the dust from the air inlet, air outlet, the
interior of the cabinet and the electronic boards.
Any signs of corrosion, especially at ground components, must be removed.