147
Appendix A - Spare Parts List
3ADW000195R0501 DCS800 Service Manual e e
8.09
2-Q 4-Q
CODE
TYPE/DATA
NOTES
1
1
3ADT220090R0022
SDCS-CMA-2
For D5 - D7 (12-pulse, hardparrallel)
1
1
DCA0019192P0001
IRDH 265-4
Inside cabinet, 10 - 990 kOhm
1
1
3ADV050058P0005
IRDH 365-4
Door mounted, 10 - 990 kOhm
1
1
3ADV050058P0001
IRDH 265-3
Inside cabinet EMBR, 2 - 200 kOhm
1
1
DCA0019711P0001
AGH 204 S
For IRDH >= 690 VAC, 6-pulse
1
1
3ADV050058P0002
AGH 150 W-4
For IRDH >= 690 VAC, 12-pulse
1
1
3ADT745047P0001
T 90, 500 -1200 VAC
For U >= 690 VAC, 12-pulse
3
3
3ADV050092P0015
CC 1051CP 10A/1000V 3 for T90 and capacitors
2
2
3ADV050092P0017
CC 1551CP 10A/1500V 2 for A92
1
1
3ADT780007R0002
SDCS-PIN-5x-1190 meas. Special test procedure & modified
1
1
3ADT220090R0031
SDCS-PAR-1
Hardparallel master
1
1
3ADT220090R0032
SDCS-PAR-2
Hardparallel slave
High volt. fuses for U >= 750 VAC
Power Interface U>=750 VAC
Item 8.09
Hardparrallel board 2
Insulation monitor
Voltage adaption for IRDH
Voltage adaption for IRDH
High volt. fuses for U >= 750 VAC
DC-DC transducer (Knick) A92
DESCRIPTION
Current measurement aid
Insulation monitor
Insulation monitor
Parts for 12-pulse, supply voltage >= 800 VAC, hardparallel D7P and galvanic isolation
Parts for 12-pulse, supply voltage >= 800 VAC, hardparallel D7P and galvanic isolation
For U >= 690 VAC, 12-pulse, replaches Knick
8680 A1/A92
1
1
3ADN260008P0001
P42000D3-0111
High volt. transformer T90
Hardparrallel board 1
10.00
2-Q 4-Q
CODE
TYPE/DATA
NOTES
1
1
3ADT313900R1501
SDCS-CON-4
Replaces 3ADT313900R1001
1
1
3ADT314100R1001
SDCS-PIN-4
OnBoard field up to 525 VAC
3
3
3ADC770032P0025
KTK 25
25 A / 600 V
1
1
3ADC340091R0001
VVZF 70-16xxx
OnBoard field up to 525 VAC
1
1
3ADT710005P0001
KTY10-6-M4/250mm
20 A - 260 A, cable 250 mm
1
1
3ADT710005P0002
KTY10-6-M4/400mm
315 A - 1000 A, cable 400 mm
2-Q 4-Q
11.00
2-Q 4-Q
CODE
TYPE/DATA
NOTES
3
6
3ADC340063P0001
SKKT27B/xxx
MCC 26 - 16 xxx
3
3
3ADT730004R0004
UR 50 A / 660 V
Blade- or knife fuse
3
3
3ADV050169P0050
UR 50 A / 600 V
When used as field in D6 or D7 cabinets
2-Q 4-Q
12.00
2-Q 4-Q
CODE
TYPE/DATA
NOTES
3
6
3ADC340063P0001
SKKT27B/xxx
MCC 26 -16 xxx
3
3
3ADT730004R0005
UR 63 A / 660 V
Blade- or knife fuse
2
2
3ADT754014P0001
CN2B2
4715 MS-12T-B5Axxx
3
3
3ADV050169P0080
UR 80 A / 600 V
When used as field in D6 or D7 cabinets
2-Q 4-Q
13.00
2-Q 4-Q
CODE
TYPE/DATA
NOTES
3
6
3ADC340067P0001
SKKT42B/xxx
MCC 44 -16 xxx
3
3
3ADT730004R0007
UR 125 A / 660 V
Blade- or knife fuse
2
2
3ADT754014P0001
CN2B2
4715 MS-12T-B5Axxx
3
3
3ADV050169P0125
UR 125 A / 600 V
When used as field in D6 or D7 cabinets
Module contains:
Module contains:
Module contains:
Control board
Interface board and field supply
Fuses on SDCS-PIN-4
Cooling fan 115 V, 50/60 Hz
Semiconductor fuses (as field)
DCS800-S01-0065-04/05 & DCS800-S02-0075-04/05 (400 V - 525 V)
Thyristor modules
DESCRIPTION
Semiconductor fuses
Thyristor modules
Semiconductor fuses
Cooling fan 115 V, 50/60 Hz
Semiconductor fuses (as field)
Semiconductor fuses
Semiconductor fuses (as field)
DCS800-S01-0045-04/05 & DCS800-S02-0050-04/05 (400 V - 525 V)
DESCRIPTION
Modules D1 - D4, 20 A - 1000 A, 400 V, 525 V and 600 V
Item 10.00 to 29.00
DESCRIPTION
Temperatur sensor (D1and D2)
Temperatur Sensor (D3 and D4)
DCS800-S01-0020-04/05 & DCS800-S02-0025-04/05 (400 V - 525 V)
Half controlled bridge block
DESCRIPTION
Thyristor modules
Common parts for modules D1 - D4, 20 A - 1000 A
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]