84
GAA610-M
ADVANCED EMISSION GAS MONITORING SYSTEM | OI/GAA610-M-EN REV. B
… 13 Maintenance
SCC-C – Replace peristaltic pump hose
CAUTION
Risk of injury due to corrosive condensates
Condensates are often corrosive. The hoses can contain
condensate residue. These materials can flow out when the
hose connections are opened.
• Take appropriate measures where needed to collect
residual condensates.
• Appropriate precautions should be taken, and relevant
regulations on disposal should be complied with.
NOTICE
Damage to components!
The hoses on the peristaltic pumps should never be
lubricated.
1
Moving belt
2
S-clip
3
Peristaltic pump hose
4
Hose connections
5
Pressure rollers
6
Dovetail guide
Figure 50: Replacing peristaltic pump hose
1. Activate the ‘Maintenance Mode’ on the control panel.
2. Turn off main switch.
Remove the old hose:
3. Remove the hoses from the hose connections
4
.
4. Using the handles, press the moving belt
1
together and
turn the s clip
2
in a clockwise direction as far as its limit
stop.
5. Remove the moving belt
1
from the pump head and pull the
old hose
3
by the hose connections
4
to release it from
the moving belt’s guides.
6. Press the pressure rollers
5
together and check the spring
pressure; if it is too weak, then the pressure springs and
possibly rollers should be replaced.
Fit a new hose:
7. Insert a new hose
3
with hose connections in the guides on
the moving belt
1
.
8. Insert moving belt
1
with the new hose in the dovetail
guide
6
in the pump head; using the handles, press the
moving belt together while at the same time turning the s-
clip
2
counterclockwise until it engages.
9. Screw hoses to the hose connections
4
.
• Take care not to kink or crush the hoses.
Restart the sample gas cooler:
10. Turn on main switch.
– The sample gas flow should only be restarted after the
lead time period.
11. Check the seal integrity according to the description in
12. Deactivate the ‘Maintenance Mode’ on the control panel.