![ABB Advance Optima Caldos 15-Ex Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/abb/advance-optima-caldos-15-ex/advance-optima-caldos-15-ex_operators-manual_3045442030.webp)
30
Advance Optima Ex Analyzer Modules Operator’s Manual
42/24-12-2 EN
Operating Specifications
EC Type Certification
DMT 01 ATEX E 037 X
Measurement function per Directive 94/9/EC, Appendix II, Paragraph 1.5.5. is not
covered by this EC type certification.
Designation
II 2G EEx d IIC T4
Level of Protection
Device Group
II
Category
2G
Explosion Protection
Ignition Suppression
Type
Pressure-tight containment “d”
Explosion Group
IIC
Temperature Class
T4
Installation Site
Risk Area
Zone 1 and Zone 2
Ambient temperature
Caldos 15-Ex, Caldos 17-Ex, Magnos 106-Ex: +5 to +50 °C
in operation
Uras 14-Ex:
+5 to +45 °C
Sample Gas Inlet
Conditions
(Atmospheric
Conditions)
Type of Gas
Non-combustible and combustible gases under
atmospheric conditions which can form an explosive
environment (Zone 1).
Temperature
Caldos 15-Ex, Caldos 17-Ex, Magnos 106-Ex: +5 to +50 °C
Uras 14-Ex:
+5 to +45 °C
Inlet Pressure
p
e
≤
100 hPa (= 0.1 bar) or p
abs
≤
1,100 hPa (= 1.1 bar)
Flow
Maximum of 100 l/h, but not greater than the non-
explosion protected version of the analyzer module.
The maximum oxygen content of the sample gas mixture should be 21 Vol.-%,
corresponding to atmospheric conditions.
If the sample gas consists only of oxygen as well as combustible gases and vapors,
it must not be explosive under any conditions. As a rule this can be achieved by
limiting oxygen content to a maximum of 2 Vol.-%.
Combustible gases that are explosive under the conditions encountered in analysis
even when oxygen is excluded should be present in the mixture only in concentra-
tions that are not critical to safety.
Continued on next page