![ABB ACS880 Series Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/abb/acs880-series/acs880-series_supplement-manual_3372978047.webp)
Fault tracing 43
6
Fault tracing
About this chapter
This chapter lists all the warning and fault messages including possible causes and
corrective actions for the Centrifuge Decanter drive.
For the complete list of warning and fault messages, see
ACS880 primary control program
firmware manual (3AUA0000085967[English])
.
Warning messages
Note:
The list also contains events that appear in the Event log.
Code
(hex)
Warning
Cause
What to do
E200
Pre wash time
too long
Pre wash speed is higher
than fill speed.
Decrease pre wash time or
prewash speed.
See parameters,
and
E201
Wash time too
long
Wash speed is higher than
spin speed.
Decrease wash time or wash
speed.
See parameters
and
.
E202
Speed feedback
not inside range
Actual speed is beyond the
minimum and maximum
speed limits.
Increase the deceleration time
from spinning speed to unloading
speed or the deceleration time
from unload speed to stop at zero
speed.
See parameters
and
.