32 Signals and parameters
Manual halt
Manual halt is active.
10
9.03
Centrifuge
reference
Shows final reference at different stages.
-
0...18000 rpm
Centrifuge reference speed.
1 = 1 rpm
9.04
Elapsed time
Shows the completed sequence time from the start
command.
-
0...32767 s
Sequence completion time in seconds.
1 = 1 s
9.05
Remaining
time
Shows the calculated value based on machine
parameters, section time and speed values.
-
0...32767 s
Remaining time in seconds.
1 = 1 s
09.10 Decanter
status word
Decanter status word. Bit representation of scroll status
information.
-
0000h...FFFFh
Decanter status word.
1 = 1
9.11
Bowl status
word
Bowl status word.
-
0000h...FFFFh
Bowl status word.
1 = 1
Actual signals
No.
Name/Value
Description
Def
/
FbEq16
Bit
Name
Description
0
Speed over limit
1 = Speed over limit reached.
1
Torque over limit 1
1 = Torque over limit 1 reached.
2
Torque over limit 2
1 = Torque over limit 2 reached.
3
D Speed reference
limit
1 = Delta speed reference limit reached.
4
Jogging active
1 = Jogging function is active.
5
Clean-up function is
active
1 = Clean-up and DC under voltage controller functions are
active.
6
Speed reference above
90% of limit
1 = Speed reference is above 90% of final speed reference.
7...15 Reserved
Bit
Name
Description
0
Ready
Bowl drive is ready to start.
1
Modulating
Bowl drive is modulating.
2
Started
Bowl drive started.
3
Remote
Bowl drive is in remote control location.
4
Tripped
Bowl drive tripped due to fault.
5
Emg stop off
Bowl drive stopped due to emergency.
6...15
Reserved