The drive is an electronic product which is covered by the European Low Voltage Directive.
The drive is equipped with a main circuit breaker which can be used in safety functions for
machinery. These safety functions are in the scope of the Machinery Directive as safety
components, and appropriate harmonized standards (EN ISO 13849 or EN 62061) shall be
applied.
Regulatory Compliance Mark (RCM)
RCM marking is pending. Applies as Compliance with EN 61800-3:2004.
EAC (Eurasian Conformity) marking
EAC (Eurasian Conformity) mark
Product complies with the technical regulations of the Eurasian Customs Union. EAC mark is required
in Russia, Belarus and Kazakhstan.
Compliance with EN 61800-3:2004/A1:2012
■
Definitions
EMC stands for Electromagnetic Compatibility. It is the ability of electrical/electronic
equipment to operate without problems within an electromagnetic environment. Likewise,
the equipment must not disturb or interfere with any other product or system within its locality.
First environment includes establishments connected to a low-voltage network which supplies
buildings used for domestic purposes.
Second environment includes establishments connected to a network not supplying domestic
premises.
Drive of category C4: drive of rated voltage equal to or above 1000 V, or rated current equal
to or above 400 A, or intended for use in complex systems in the second environment.
■
Category C4
The requirements of the standard can be met as follows:
1.
It is ensured that no excessive emission is propagated to neighbouring low-voltage
networks. In some cases, the natural suppression in transformers and cables is sufficient.
If in doubt, the supply transformer with static screening between the primary and
secondary windings can be used.
1
2
3
4
5
6
7
8
9
4
6
Equipment
6
Medium voltage network
1
96 Technical data
Содержание ACS880-77CC
Страница 1: ...ABB WIND TURBINE CONVERTERS ACS880 77CC wind turbine converters Hardware manual...
Страница 2: ......
Страница 4: ......
Страница 10: ...10...
Страница 17: ...5 1 3 4 6 8 7 2 Safety instructions 17...
Страница 22: ...22...
Страница 40: ...40...
Страница 60: ...60...
Страница 73: ...2a 3b 4c 5 Air flow direction is towards the converter module Maintenance 73...
Страница 104: ...104...
Страница 108: ...Description CAN bus connection XCAN XCAN 108 BCU x5 control unit...
Страница 112: ...112 Dimension drawings...
Страница 113: ...Dimension drawings 113...
Страница 114: ...114 Dimension drawings...
Страница 126: ...126...