Connector data
Connector pitch 5 mm, wire size 2.5 mm
2
Power supply (XPOW)
24 V (±10%) DC, 2 A
External power input.
Two supplies can be connected to BCU for redundancy.
Connector pitch 5 mm, wire size 2.5 mm
2
Relay outputs RO1…RO3
(XRO1…XRO3)
250 V AC / 30 V DC, 2 A
Protected by varistors
Connector pitch 5 mm, wire size 2.5 mm
2
+24 V output (XD24:2 and XD24:4)
Total load capacity of these outputs is 4.8 W (200 mA / 24 V) minus
the power taken by DIO1 and DIO2.
Connector pitch 5 mm, wire size 2.5 mm
2
Digital inputs DI1…DI6 (XDI:1…XDI:6)
24 V logic levels: “0” < 5 V, “1” > 15 V
R
in
: 2.0 kohm
Input type: NPN/PNP (DI1…DI5), NPN (DI6)
Hardware filtering: 0.04 ms, digital filtering up to 8 ms
DI6 (XDI:6) can alternatively be used as an input for a PTC sensor.
“0” > 4 kohm, “1” < 1.5 kohm.
I
max
: 15 mA (DI1…DI5), 5 mA (DI6)
Connector pitch 5 mm, wire size 2.5 mm
2
Start interlock input DIIL (XDI:7)
24 V logic levels: “0” < 5 V, “1” > 15 V
R
in
: 2.0 kohm
Input type: NPN/PNP
Hardware filtering: 0.04 ms, digital filtering up to 8 ms
Connector pitch 5 mm, wire size 2.5 mm
2
Digital inputs/outputs DIO1 and DIO2
(XDIO:1 and XDIO:2)
As inputs: 24 V logic levels: “0” < 5 V, “1” > 15 V.
R
in
: 2.0 kohm. Fil-
tering: 1 ms.
Input/output mode selection by paramet-
ers.
As outputs: Total output current from +24VD is limited to 200 mA
DIO1 can be configured as a frequency
input (0…16 kHz with hardware filtering
of 4 microseconds) for 24 V level square
wave signal (sinusoidal or other wave
form cannot be used). DIO2 can be con-
figured as a 24 V level square wave fre-
quency output. See the firmware manual,
parameter group 11/111.
R
L
DIOx
DIOGND
+24VD
Connector pitch 5 mm, wire size 2.5 mm
2
Reference voltage for analog inputs
+VREF and -VREF (XAI:1 and XAI:2)
10 V ±1% and –10 V ±1%,
R
load
1…10 kohm
Maximum output current: 10 mA
Connector pitch 5 mm, wire size 2.5 mm
2
Analog inputs AI1 and AI2
(XAI:4 … XAI:7).
Current input: –20…20 mA,
R
in
= 100 ohm
Current/voltage input mode selection by
switches
Voltage input: –10…10 V,
R
in
> 200 kohm
Differential inputs, common mode range ±30 V
Sampling interval per channel: 0.25 ms
Hardware filtering: 0.25 ms, adjustable digital filtering up to 8 ms
Resolution: 11 bit + sign bit
Inaccuracy: 1% of full scale range
BCU-x5 control unit 109
Содержание ACS880-77CC
Страница 1: ...ABB WIND TURBINE CONVERTERS ACS880 77CC wind turbine converters Hardware manual...
Страница 2: ......
Страница 4: ......
Страница 10: ...10...
Страница 17: ...5 1 3 4 6 8 7 2 Safety instructions 17...
Страница 22: ...22...
Страница 40: ...40...
Страница 60: ...60...
Страница 73: ...2a 3b 4c 5 Air flow direction is towards the converter module Maintenance 73...
Страница 104: ...104...
Страница 108: ...Description CAN bus connection XCAN XCAN 108 BCU x5 control unit...
Страница 112: ...112 Dimension drawings...
Страница 113: ...Dimension drawings 113...
Страница 114: ...114 Dimension drawings...
Страница 126: ...126...