6. Install temporary grounding as required by the local regulations.
7.
Ask for a permit to work from the person in control of the electrical installation
work.
■
Additional instructions and notes
WARNING!
Obey these instructions. If you ignore them, injury or death, or damage to
the equipment can occur.
If you are not a qualified electrical professional, do not do installation or
maintenance work.
•
Make sure that the electrical power network, motor/generator, and
environmental conditions agree with the drive data.
•
Do not do insulation or voltage withstand tests on the drive.
•
If you have a cardiac pacemaker or other electronic medical device, keep away
from the area near motor, drive, and the drive power cabling when the drive
is in operation. There are electromagnetic fields present which can interfere
with the function of such devices. This can cause a health hazard.
Note:
•
When the drive is connected to the input power, the motor cable terminals
and the DC bus are at a dangerous voltage.
The brake circuit, including the brake chopper and brake resistor (if installed)
are also at a dangerous voltage.
After disconnecting the drive from the input power, these remain at a
dangerous voltage until the intermediate circuit capacitors have discharged.
•
External wiring can supply dangerous voltages to the relay outputs of the
control units of the drive.
•
The Safe torque off function does not remove the voltage from the main and
auxiliary circuits. The function is not effective against deliberate sabotage or
misuse.
Printed circuit boards
WARNING!
Use a grounding wristband when you handle printed circuit boards. Do not
touch the boards unnecessarily. The boards contain components sensitive
to electrostatic discharge.
Safety instructions 25
Содержание ACS580 Series
Страница 1: ...ABB GENERAL PURPOSE DRIVES ACS580 01 drives Hardware manual...
Страница 2: ......
Страница 4: ......
Страница 19: ...Further information Table of contents 19...
Страница 20: ...20...
Страница 34: ...34...
Страница 58: ...58...
Страница 128: ...128...
Страница 163: ...R5 4 6 11 11 10 4 3 5 7 8 9 0 5 0 6 N m 0 4 lbf ft 8 4 Electrical installation Global IEC 163...
Страница 206: ...R5 DC DC L1 L2 L3 T1 U T2 W T2 V 11 11 7 3 9 5 10 6 4 R5 0 4 lbf ft 206 Electrical installation North America...
Страница 207: ...R6 R9 11 11 7 3 9 5 10 6 4 R6 R9 0 4 lbf ft Electrical installation North America 207...
Страница 214: ...214...
Страница 227: ...Note Only 24 V DC can be used for STO Only PNP input configuration can be used Control unit 227...
Страница 236: ...236...
Страница 240: ...240...
Страница 242: ...242...
Страница 258: ...3a 3b 3c 4 5 7 6 2d 2a 2b 2c 258 Maintenance...
Страница 364: ...Frame R1 IP21 UL Type 1 3AXD10000601652 364 Dimension drawings...
Страница 365: ...Frame R1 IP55 UL Type 12 3AXD10000601699 Dimension drawings 365...
Страница 366: ...Frame R1 IP55 F278 UL Type 12 366 Dimension drawings...
Страница 367: ...Frame R1 IP66 UL Type 4X B066 3AXD50001012694 Dimension drawings 367...
Страница 368: ...Frame R1 IP66 UL Type 4X B063 3AXD50001012694 368 Dimension drawings...
Страница 369: ...Frame R1 IP66 UL Type 4X C193 3AXD50001012694 Dimension drawings 369...
Страница 370: ...Frame R2 IP21 UL Type 1 3AXD10000602398 370 Dimension drawings...
Страница 371: ...Frame R2 IP55 UL Type 12 3AXD10000602401 Dimension drawings 371...
Страница 372: ...Frame R2 IP55 F278 UL Type 12 372 Dimension drawings...
Страница 373: ...Frame R2 IP66 UL Type 4X B066 3AXD50000999286 Dimension drawings 373...
Страница 374: ...Frame R2 IP66 UL Type 4X B063 3AXD50000999286 374 Dimension drawings...
Страница 375: ...Frame R2 IP66 UL Type 4X C193 3AXD50000999286 Dimension drawings 375...
Страница 376: ...Frame R3 IP21 UL Type 1 3AXD10000602466 376 Dimension drawings...
Страница 377: ...Frame R3 IP55 UL Type 12 3AXD10000602519 Dimension drawings 377...
Страница 378: ...Frame R3 IP55 E223 UL Type 12 378 Dimension drawings...
Страница 379: ...Frame R3 IP55 F278 F316 UL Type 12 Dimension drawings 379...
Страница 380: ...Frame R3 IP66 UL Type 4X B066 3AXD50001013059 380 Dimension drawings...
Страница 381: ...Frame R3 IP66 UL Type 4X B063 3AXD50001013059 Dimension drawings 381...
Страница 382: ...Frame R3 IP66 UL Type 4X C193 3AXD50001013059 382 Dimension drawings...
Страница 383: ...Frame R4 IP21 UL Type 1 3AXD10001330082 Dimension drawings 383...
Страница 384: ...Frame R4 IP55 UL Type 12 3AXD10001330271 384 Dimension drawings...
Страница 385: ...Frame R4 IP55 E223 UL Type 12 3AXD10001373680 Dimension drawings 385...
Страница 386: ...Frame R4 IP55 F278 F316 UL Type 12 3AXD10001373680 386 Dimension drawings...
Страница 387: ...Frame R5 IP21 UL Type 1 3AXD10000427933 Dimension drawings 387...
Страница 388: ...Frame R5 IP55 UL Type 12 3AXD10000386017 388 Dimension drawings...
Страница 389: ...Frame R5 IP55 E223 UL Type 12 Dimension drawings 389...
Страница 390: ...Frame R5 IP55 F278 F316 UL Type 12 390 Dimension drawings...
Страница 391: ...Frame R6 IP21 UL Type 1 3AXD10000258705 Dimension drawings 391...
Страница 392: ...Frame R6 IP55 UL Type 12 3AXD10000330667 392 Dimension drawings...
Страница 393: ...Frame R7 IP21 UL Type 1 3AXD10000258995 Dimension drawings 393...
Страница 394: ...Frame R7 IP55 UL Type 12 3AXD10000330932 394 Dimension drawings...
Страница 395: ...Frame R8 IP21 UL Type 1 3AXD10000287670 Dimension drawings 395...
Страница 396: ...Frame R8 IP55 UL Type 12 3AXD10000332446 396 Dimension drawings...
Страница 397: ...Frame R9 IP21 UL Type 1 3AXD10000287428 Dimension drawings 397...
Страница 398: ...Frame R9 IP55 UL Type 12 3AXD10000334310 398 Dimension drawings...
Страница 437: ...Dimension drawings The dimensions are in millimeters Optional I O extension and adapter modules 437...
Страница 459: ...Optional I O extension and adapter modules 459...
Страница 460: ...460...