![ABB ACS580-04 Скачать руководство пользователя страница 258](http://html.mh-extra.com/html/abb/acs580-04/acs580-04_hardware-manual_2579258.webp)
Default
Setting
Parameter
No action
Fault
32.06 Supervision 1 action
Frequency
AI1
32.07 Supervision 1 signal
0.00
0.4
32.09 Supervision 1 low
Diagnostics
■
LEDs
The adapter module has one diagnostic LED.
Description
Color
The adapter module is powered up.
Green
Technical data
Into SLOT 2 on the drive control unit
Installation
IP20
Degree of protection
See the drive technical data.
Ambient conditions
Cardboard
Package
Analog inputs (80…82, 83…85)
1.5 mm
2
Maximum wire size
-10 V … +10 V
Input voltage (AI+ and
AI-)
> 200 kohm
Input resistance
Optional cable shield connection
Analog outputs (86…88, 89…91)
1.5 mm
2
Maximum wire size
0 V … +10 V
Output voltage (AO+ and
AGND)
< 20 ohm
Output resistance
> 10 kohm
Recommended load
typical ±1%, max. ±1.5% of full scale
Inaccuracy
Optional cable shield connection
Analog output scale switch
0.5 V … 9.5 V range in use
ON state
0 V …10 V range in use
OFF state
Isolation areas
258 CBAI-01 bipolar analog IO adapter module
Содержание ACS580-04
Страница 1: ... ABB GENERAL PURPOSE DRIVES ACS580 04 drive modules Hardware manual ...
Страница 2: ......
Страница 4: ......
Страница 26: ...26 ...
Страница 60: ...60 ...
Страница 69: ...2 1 Tapping screw M6 12 Torx T30 Hex 9 N m 6 6 lbf ft Mechanical installation 69 10 ...
Страница 72: ...72 ...
Страница 100: ...100 ...
Страница 120: ...120 ...
Страница 128: ...2 7a 7b 5 3 3 7a 7b 8a 8b 8b 4 128 Installation example with full cabling panels option H381 ...
Страница 133: ...Installation example with full cabling panels option H381 133 ...
Страница 134: ...134 ...
Страница 146: ...146 ...
Страница 157: ...External control unit option P906 157 ...
Страница 158: ...Dimension drawing The dimensions are in millimeters and inches 158 External control unit option P906 ...
Страница 162: ...162 ...
Страница 164: ...164 ...
Страница 200: ...R10 standard configuration 200 Dimension drawings ...
Страница 201: ...R10 with options E208 0H354 H356 H370 0H371 Dimension drawings 201 ...
Страница 202: ...R10 with option B051 202 Dimension drawings ...
Страница 203: ...R10 with options E208 H356 P906 Dimension drawings 203 ...
Страница 204: ...R10 with options E208 0H371 H356 0H354 H370 P906 204 Dimension drawings ...
Страница 205: ...R10 with options B051 P906 Dimension drawings 205 ...
Страница 207: ...R10 Cabling panels H381 installed into a Rittal VX25 enclosure 3AXD50000439317 Dimension drawings 207 ...
Страница 208: ...R11 standard configuration 208 Dimension drawings ...
Страница 209: ...R11 with options E208 0H371 H356 0H354 H370 Dimension drawings 209 ...
Страница 210: ...R11 with option B051 210 Dimension drawings ...
Страница 211: ...R11 with options E208 H356 P906 Dimension drawings 211 ...
Страница 212: ...R11 with options E208 0H371 H356 0H354 H370 P906 212 Dimension drawings ...
Страница 213: ...R11 with options B051 P906 Dimension drawings 213 ...
Страница 215: ...R11 Cabling panels H381 installed into a Rittal VX25 enclosure 3AXD50000438938 Dimension drawings 215 ...
Страница 248: ...248 ...
Страница 254: ...Dimension drawings The dimensions are in millimeters 254 CAIO 01 bipolar analog I O adapter module ...
Страница 260: ...260 ...
Страница 265: ...CHDI 01 115 230 V digital input extension module 265 ...
Страница 266: ...266 ...
Страница 272: ...272 CMOD 01 multifunction extension module external 24 V AC DC and digital I O ...
Страница 278: ...278 ...
Страница 280: ...280 ...