Surrounding air temperature derating
Installation with 50mm space
between
Install side-by-side
Frame
0%
20%
40%
60%
80%
100%
-10
0
10 20 30 40 50 60
Derating
factor
Ambient temperature
(°C)
(°F)
140
122
104
86
68
50
32
14
0%
20%
40%
60%
80%
100%
-10
0
10 20 30 40 50 60
Derating
factor
Ambient temperature
(°C)
(°F)
140
122
104
86
68
50
32
14
Derating factor for
IHd
(Heavy duty rating,
150% overloadabil-
ity)
R0
0%
20%
40%
60%
80%
100%
-10
0
10 20 30 40 50 60
Derating
factor
Ambient temperature
(°C)
(°F)
140
122
104
86
68
50
32
14
0%
25%
50%
75%
100%
Derating
factor
-10
0
10 20 30 40 50 60
Ambient temperature
(°C)
(°F)
140
122
104
86
68
50
32
14
Derating factor for
IN and ILd
(Normal and light
duty rating, no or
110% overloadabil-
ity)
0%
25%
50%
75%
100%
Derating
factor
-10
0
10 20 30 40 50 60 70
Ambient temperature
(°C)
(°F)
158
140
122
104
86
68
50
32
14
Derating factor for
IHd
R1
0%
20%
40%
60%
80%
100%
Derating
factor
65%
-10
0
10 20 30 40 50 60 70
Ambient temperature
(°C)
(°F)
158
140
122
104
86
68
50
32
14
Derating factor for
IN and ILd
Technical data 97
Содержание ACS180
Страница 1: ...ABB MACHINERY DRIVES ACS180 drives Hardware manual...
Страница 2: ......
Страница 4: ......
Страница 12: ...12...
Страница 36: ...36...
Страница 41: ...4 Tighten the mounting screws Mechanical installation 41...
Страница 58: ...58...
Страница 76: ...76...
Страница 90: ...90...
Страница 130: ...Frame R0 130 Dimension drawings...
Страница 131: ...Frame R1 Dimension drawings 131...
Страница 133: ...Frame R3 Dimension drawings 133...
Страница 134: ...Frame R4 134 Dimension drawings...
Страница 142: ...142...
Страница 162: ...Declarations of conformity 162 The Safe torque off function...
Страница 163: ...The Safe torque off function 163...
Страница 164: ...164 The Safe torque off function...
Страница 165: ...The Safe torque off function 165...
Страница 166: ...166...