6. Replace the fan. Make sure that the air flow is in the correct direction. The air
flows in from the bottom of the drive and out from the top of the drive.
7.
Connect the fan power cable.
6
7
8. Place the fan cover back on the frame.
9. Push the cover to lock into position.
8
9
Capacitors
The DC link of the drive contains several electrolytic capacitors. Operating time,
load, and surrounding air temperature have an effect on the life of the capacitors.
Capacitor life can be extended by decreasing the surrounding air temperature.
Capacitor failure is usually followed by damage to the unit and an input cable fuse
failure, or a fault trip. If you think that any capacitors in the drive have failed,
contact ABB.
■
Reforming the capacitors
The capacitors must be reformed if the drive has not been powered (either in
storage or unused) for a year or more. The manufacturing date is on the type
designation label. For information on reforming the capacitors, refer to
reforming instructions (3BFE64059629 [English])
.
Maintenance 89
Содержание ACS180
Страница 1: ...ABB MACHINERY DRIVES ACS180 drives Hardware manual...
Страница 2: ......
Страница 4: ......
Страница 12: ...12...
Страница 36: ...36...
Страница 41: ...4 Tighten the mounting screws Mechanical installation 41...
Страница 58: ...58...
Страница 76: ...76...
Страница 90: ...90...
Страница 130: ...Frame R0 130 Dimension drawings...
Страница 131: ...Frame R1 Dimension drawings 131...
Страница 133: ...Frame R3 Dimension drawings 133...
Страница 134: ...Frame R4 134 Dimension drawings...
Страница 142: ...142...
Страница 162: ...Declarations of conformity 162 The Safe torque off function...
Страница 163: ...The Safe torque off function 163...
Страница 164: ...164 The Safe torque off function...
Страница 165: ...The Safe torque off function 165...
Страница 166: ...166...