7.7.1.4. Preparing cables for cable entries with cable glands
–
Prepare the cables with an outer cable screen for EMC bonding with the metal
enclosure of the cabinet as illustrated in Fig. 7
Figure 7
-
21 Preparing control cables for cable glands
1) Outer cable sheath
2) Cable gland
3) Conductor insulation removed to expose
cable shield
4) Plate
5) Conductor screen extension to be
connected to PE terminal
1
5
2
3