![ABB ACS 600 Series Скачать руководство пользователя страница 78](http://html1.mh-extra.com/html/abb/acs-600-series/acs-600-series_hardware-manual_3379279078.webp)
Appendix C – IEC Installation
C-8
ACx=ACS/ACC/ACP
ACS/ACC/ACP 604/607 Drives
Control Cable
Connecting Procedure
To connect the control cables for ACx 607 carry out the following
procedure:
1. Loosen the
lead-through plate position screws. Pull the two parts
apart.
2. Lead the cable inside the cabinet through the
EMI conductive
cushions.
3. Strip off the cable plastic sheath above the
base plate (only a
distance wide enough to ensure proper connection of the bare
screen and the
EMI conductive cushions).
4. Earth the screen between the
EMI conductive cushions:
a. If the outer surface of the screen is conductive:
-
Push the two parts of the
lead-through plate together so that the
EMI conductive cushions press tightly round the bare screen.
EMI conductive cushions
Base plate
Holes for
position screws
Side view
Top view
Lead-through plate