Appendix A – ACS/ACC/ACP 604/607 Technical Data
A-16
ACx=ACS/ACC/ACP
ACS/ACC/ACP 604/607 Drives
Digital Inputs
ACS/ACP 600: Six Programmable Digital
Inputs (Common Ground): 24 VDC, -15% to
+20%
ACC 600: Six Digital Inputs (Common
Ground): 24 VDC, -15% to +20%
Logical Thresholds: < 8 VDC
“0”,
> 12 VDC
“1”
Input Current: DI1 to DI 5: 10 mA, DI6: 5 mA
Filtering Time Constant: 1 ms
Thermistor Input: 5 mA, < 1.5 k
Ω
“1”
(normal temperature), > 4 k
Ω
“0”
(high
temperature), Open Circuit
“0” (high
temperature)
Internal Supply For Digital Inputs
(+24 VDC): Short circuit proof, group isolated
Isolation Test Voltage: 500 VAC, 1 minute
Input Updating Time: 12 ms (ACS 600),
44 ms (ACC 600), 4 ms (ACP 600)
An external 24 VDC supply can be used
instead of the internal supply.
12 Programmable Digital Inputs (Common
Ground): 24 VDC, -15% to +20%
Logical Thresholds: < 8 VDC
“0”,
> 12 VDC
“1”
Filtering Time Constant:
≤
50
µ
s
DI 11 and DI 12 can be used for time
measurement between two external events
(PROBE1 and PROBE2).
Internal Supply For Digital Inputs
(+24 VDC): Short circuit proof, group isolated
Isolation Test Voltage: 500 VAC, 1 minute
Input Updating Time: 1 ms
An external 24 VDC supply can be used
instead of the internal supply.
Filtering Time Constant:
≤
100
µ
s
Digital Outputs
-
Four Programmable Digital Outputs: Short
circuit proof, Overload protection
Maximum Load: 10 mA with internal 24 V
supply, 100 mA with external supply
Output Updating Time: 2 ms
Relay Outputs
Three Programmable Relay Outputs
Switching Capacity: 8 A at 24 VDC or
250 VAC, 0.4 A at 120 VDC
Minimum Continuous Current: 5 mA rms at
24 VDC
Maximum Continuous Current: 2 A rms
Contact Material: Silver Cadmium Oxide
(AgCdO)
Isolation Test Voltage: 4 kVAC, 1 minute
Output Updating Time: 100 ms (ACS 600),
44 ms (ACC 600), 8 ms (ACP 600)
One Relay Output
Switching Capacity: 8 A at 24 VDC or
250 VAC, 0.4 A at 120 VDC
Minimum Continuous Current: 5 mA rms at
24 VDC
Max Continuous Current: 2 A rms
Contact Material: Silver Cadmium Oxide
(AgCdO)
Isolation Test Voltage: 4 kVAC, 1 minute
Output Updating Time: 2 ms
DDCS Fiber Optic
Link
Protocol: DDCS (ABB Distributed Drives Communication System)
ACS/ACC/ACP 600
NIOC-01 Board
ACP 600
NIOCP-01 Board
Содержание ACS 600 Series
Страница 2: ......
Страница 4: ......
Страница 16: ...xiv ACx ACS ACC ACP ACS ACC ACP 604 607 Drives ...
Страница 20: ...Chapter 1 Introduction 1 4 ACx ACS ACC ACP ACS ACC ACP 604 607 Drives ...
Страница 38: ...Chapter 5 Maintenance 5 2 ACx ACS ACC ACP ACS ACC ACP 604 607 Drives ...
Страница 72: ...Appendix B ACx 607 Dimensional Drawings B 2 ACx ACX ACC ACP ACS ACC ACP 604 607 Drives ...
Страница 81: ......