![ABB ACQ580-34 Скачать руководство пользователя страница 113](http://html.mh-extra.com/html/abb/acq580-34/acq580-34_hardware-manual_2546113.webp)
Default I/O connection diagram
The default control connections for the Water default are shown below.
500 ohm
Max.
1…10 kohm
X1
1
SCR
Reference voltage and analog inputs and outputs
2
AI1
Signal cable shield (screen)
3
AGND
Output frequency/speed reference
: 0…10 V
1)
4
+10V
Analog input circuit common
5
AI2
Reference voltage 10 V DC
6
Actual feedback:
0…10 V
AGND
7
AO1
8
AO2
Analog input circuit common
Output frequency:
0…10 V
9
AGND
Output current:
0…20 mA
Analog output circuit common
10
+24V
X2 & X3
Aux. voltage output and programmable digital inputs
11
DGND
Aux. voltage 24 V DC, max. 250 mA
2)
12
DCOM
Aux. voltage output common
13
DI1
Digital input common for all
14
DI2
Stop (0) / Start (1)
15
DI3
Not configured
16
DI4
Constant frequency/speed selection
3)
17
Not configured
DI5
18
Not configured
DI6
X6, X7, X8
Not configured
19
RO1C
Relay outputs
20
RO1A
21
RO1B
Ready run
250 V AC / 30 V DC
2 A
22
RO2C
23
RO2A
24
RO2B
Running
250 V AC / 30 V DC
2 A
25
RO3C
26
RO3A
27
RO3B
X5
Fault (-1)
250 V AC / 30 V DC
2 A
29
B+
Embedded fieldbus
30
A-
31
DGND
S4
TERM
Embedded fieldbus, EFB (EIA-485)
S5
BIAS
Termination switch
X4
Bias resistors switch
34
Safe torque off
OUT1
35
OUT2
36
SGND
37
IN1
38
IN2
X10
40
24 V AC/DC
41
Safe torque off. Factory connection. Both
circuits must be closed for the drive to start. See
chapter
Safe torque off function
24 V AC/DC+ in
24 V AC/DC- in
Ext. 24V AC/DC input to power up the control unit
when the main supply is disconnected.
7)
4)
6)
4) 4)
5)
1)
Total load capacity of the Auxiliary voltage 24V (X2:10) is 6.0 W (250 mA / 24 V DC).
Digital inputs DI1…DI5 also support 10 to 24 V AC
Terminal sizes: 0.14…2.5 mm
2
(all terminals)
Tightening torques: 0.5…0.6 N·m (0.4 lbf·ft)
Notes:
Control unit 113
Содержание ACQ580-34
Страница 1: ... ABB DRIVES FOR WATER ACQ580 34 drive modules Hardware manual ...
Страница 2: ......
Страница 4: ......
Страница 14: ...14 ...
Страница 24: ...24 ...
Страница 50: ...50 ...
Страница 60: ...60 ...
Страница 70: ...70 ...
Страница 94: ...94 ...
Страница 110: ...110 ...
Страница 122: ...122 ...
Страница 132: ...Dimension drawing 132 External control unit option P906 ...
Страница 140: ...140 ...
Страница 144: ...144 ...
Страница 164: ...164 ...
Страница 184: ...Standard configuration E208 and E210 included 184 Dimension drawings ...
Страница 185: ...Drive module with option B051 Dimension drawings 185 ...
Страница 186: ...Drive module with options B051 H370 186 Dimension drawings ...
Страница 187: ...LCL filter module Dimension drawings 187 ...
Страница 190: ...190 ...
Страница 208: ... Declaration of conformity 208 The Safe torque off function ...
Страница 214: ...214 ...
Страница 226: ...226 ...