Name
Standard
Electromagnetic compatibility (EMC) – Part 6-7: Generic stand-
ards – Immunity requirements for equipment intended to perform
functions in a safety-related system (functional safety) in indus-
trial locations
IEC 61000-6-7:2014
Electrical equipment for measurement, control and laboratory
use – EMC requirements – Part 3-1: Immunity requirements for
safety-related systems and for equipment intended to perform
safety-related functions (functional safety) – General industrial
applications
IEC 61326-3-1:2017
Functional safety of electrical/electronic/programmable electronic
safety-related systems – Part 1: General requirements
IEC 61508-1:2010
Functional safety of electrical/electronic/programmable electronic
safety-related systems – Part 2: Requirements for electrical/elec-
tronic/programmable electronic safety-related systems
IEC 61508-2:2010
Functional safety – Safety instrumented systems for the process
industry sector
IEC 61511-1:2016
Adjustable speed electrical power drive systems – Part 5-2:
Safety requirements – Functional
IEC 61800-5-2:2016
EN 61800-5-2:2007
Safety of machinery – Functional safety of safety-related electric-
al, electronic and programmable electronic control systems
IEC 62061:2005 + A1:2012 +
A2:2015
EN 62061:2005 + AC:2010 +
A1:2013 + A2:2015
Safety of machinery – Safety-related parts of control systems –
Part 1: General principles for design
EN ISO 13849-1:2015
Safety of machinery – Safety-related parts of control systems –
Part 2: Validation
EN ISO 13849-2:2012
The function also corresponds to Prevention of unexpected start-up as specified by
EN ISO 14118:2018 (ISO 14118:2017), and Uncontrolled stop (stop category 0) as
specified in EN/IEC 60204-1.
■
Compliance with the European Machinery Directive
See the technical data.
The Declaration of conformity is shown at the end of this chapter.
274 The Safe torque off function
Содержание ACQ580-07
Страница 1: ... ABB DRIVES FOR WATER ACQ580 07 Hardware manual ...
Страница 2: ......
Страница 4: ......
Страница 8: ...4 Update notice ...
Страница 20: ...16 ...
Страница 26: ...Measuring points of frames R6 to R9 are shown below PE L1 L2 L3 22 Safety instructions ...
Страница 32: ...28 ...
Страница 38: ...34 ...
Страница 66: ...62 ...
Страница 69: ...Mechanical installation 65 ...
Страница 73: ... Mechanical installation 69 ...
Страница 75: ...Declaration of Conformity Mechanical installation 71 ...
Страница 108: ...104 ...
Страница 133: ...Electrical installation 129 ...
Страница 134: ...The route of the control cables for frames R10 and R11 is shown below X504 L504 130 Electrical installation ...
Страница 142: ...138 ...
Страница 156: ...152 ...
Страница 162: ...158 ...
Страница 166: ...Replacing the air filters IP54 UL Type 12 Check the air filters and replace if necessary 162 Maintenance ...
Страница 171: ...Maintenance 167 ...
Страница 177: ...3 4 Maintenance 173 ...
Страница 184: ...14 13 15 16 17 Remove the flange 180 Maintenance ...
Страница 187: ...3 4 5 6 Remove the mounting plate Maintenance 183 ...
Страница 189: ...8 Disconnect the drive module output busbars M12 70 N m 52 lbf ft 7 8 Maintenance 185 ...
Страница 193: ...4 5 3 6 Remove the mounting plate Maintenance 189 ...
Страница 195: ...8 Disconnect the drive module output busbars M12 70 N m 52 lbf ft 7 8 Maintenance 191 ...
Страница 217: ...Frame R6 Input and motor cable terminal dimensions bottom entry and exit switch fuse OS400 DET A Technical data 213 ...
Страница 218: ...Frame R6 Input and motor cable terminal dimensions option F289 DET A 214 Technical data ...
Страница 222: ...Frame R7 Input and motor cable terminal dimensions bottom entry and exit switch fuse OS250 DET A 218 Technical data ...
Страница 223: ...Frame R7 Input and motor cable terminal dimensions bottom entry and exit switch fuse OS400 DET A Technical data 219 ...
Страница 224: ...Frame R7 Input and motor cable terminal dimensions bottom entry and exit option F289 220 Technical data ...
Страница 225: ...Frames R6 and R7 Input and motor cable terminal dimensions top entry and exit options H351 and H353 Technical data 221 ...
Страница 228: ...Frame R8 Input and motor cable terminal dimensions bottom entry and exit option F289 224 Technical data ...
Страница 231: ...Frames R8 and R9 Input and motor cable terminal dimensions top entry and exit options H351 and H353 Technical data 227 ...
Страница 233: ...Frame R9 Input and motor cable terminal dimensions option F289 Technical data 229 ...
Страница 257: ...13 Dimension drawings Example dimension drawings are shown below Dimension drawings 253 ...
Страница 258: ...Frames R6 and R7 IP21 UL Type 1 254 Dimension drawings ...
Страница 259: ...Frames R6 and R7 B054 IP42 UL Type 1 Filtered Dimension drawings 255 ...
Страница 260: ...Frames R6 and R7 B055 IP54 UL Type 12 256 Dimension drawings ...
Страница 261: ...Frames R6 and R7 H351 and H353 top entry and exit Dimension drawings 257 ...
Страница 262: ...Frames R6 and R7 F289 258 Dimension drawings ...
Страница 263: ...Frames R6 and R7 F289 H351 H353 Dimension drawings 259 ...
Страница 264: ...Frames R8 and R9 IP21 UL Type 1 260 Dimension drawings ...
Страница 265: ...Frames R8 and R9 B054 IP42 UL Type 1 Filtered Dimension drawings 261 ...
Страница 266: ...Frames R8 and R9 B055 IP54 UL Type 12 262 Dimension drawings ...
Страница 267: ...Frames R8 and R9 H351 and H353 top entry and exit Dimension drawings 263 ...
Страница 268: ...Frames R8 and R9 F289 264 Dimension drawings ...
Страница 269: ...Frames R8 and R9 F289 H351 H353 Dimension drawings 265 ...
Страница 295: ... Declaration of conformity The Safe torque off function 291 ...
Страница 296: ...292 ...
Страница 302: ...298 ...
Страница 309: ...CMOD 01 multifunction extension module external 24 V AC DC and digital I O 305 ...
Страница 310: ...306 ...
Страница 316: ...312 CMOD 02 multifunction extension module external 24 V AC DC and isolated PTC interface ...
Страница 322: ...318 ...