![background image](http://html.mh-extra.com/html/abb/ach480/ach480_hardware-manual_2507040.webp)
•
You can install frames R1, R2, R3 and R4 tilted by up to 90 degrees from vertical
to fully horizontal orientation.
•
Make sure that the hot exhaust air from a drive does not flow into the cooling inlet
of other drives or equipment.
•
Drives equipped with the optional UL Type 1 kits: If you install the drives side-by-side,
make sure that their air outlets do not face each other.
Examining the installation site
Examine the installation site. Make sure that:
•
The installation site is sufficiently ventilated or cooled to remove heat from the drive.
See the technical data.
•
The ambient conditions of the drive meet the specifications. See the technical data.
•
The wall behind the unit and the material above and below the unit is of
non-flammable material.
•
The installation surface is as close to vertical as possible and strong enough to
support the drive.
•
There is sufficient free space around the drive for cooling, maintenance, and
operation. See the free space specifications for the drive.
•
Make sure that there are no sources of strong magnetic fields such as high-current
single-core conductors or contactor coils near the drive. A strong magnetic field can
cause interference or inaccuracy in the operation of the drive.
Required tools
To install the drive mechanically, you need the following tools:
•
a drill and suitable drill bits
•
a screwdriver or wrench with a set of suitable bits
•
a tape measure and spirit level
•
personal protective equipment.
40 Mechanical installation
4
Содержание ACH480
Страница 1: ... ABB DRIVES FOR HVAC ACH480 drives Hardware manual ...
Страница 2: ......
Страница 4: ......
Страница 14: ...14 ...
Страница 22: ...22 ...
Страница 28: ...28 ...
Страница 38: ...38 ...
Страница 44: ...44 ...
Страница 60: ...60 ...
Страница 86: ...86 ...
Страница 110: ...110 ...
Страница 114: ...114 ...
Страница 122: ...122 ...
Страница 156: ...Frame R1 Frame R1 front side IP20 UL open type 156 Dimension drawings ...
Страница 157: ... Frame R1 bottom rear IP20 UL open type Dimension drawings 157 ...
Страница 158: ... Frame R1 front side UL Type 1 kit installed 158 Dimension drawings ...
Страница 159: ... Frame R1 bottom rear UL Type 1 kit installed Dimension drawings 159 ...
Страница 160: ...Frame R2 Frame R2 front side IP20 UL open type 160 Dimension drawings ...
Страница 161: ... Frame R2 bottom rear IP20 UL open type Dimension drawings 161 ...
Страница 162: ... Frame R2 front side UL Type 1 kit installed 162 Dimension drawings ...
Страница 163: ... Frame R2 bottom rear UL Type 1 kit installed Dimension drawings 163 ...
Страница 164: ...Frame R3 Frame R3 front side IP20 UL open type 164 Dimension drawings ...
Страница 165: ... Frame R3 bottom rear IP20 UL open type Dimension drawings 165 ...
Страница 166: ... Frame R3 front side UL Type 1 kit installed 166 Dimension drawings ...
Страница 167: ... Frame R3 bottom rear UL Type 1 kit installed Dimension drawings 167 ...
Страница 168: ...Frame R4 Frame R4 front side IP20 UL open type 168 Dimension drawings ...
Страница 169: ... Frame R4 bottom rear IP20 UL open type Dimension drawings 169 ...
Страница 170: ... Frame R4 front side UL Type 1 kit installed 170 Dimension drawings ...
Страница 171: ... Frame R4 bottom rear UL Type 1 kit installed Dimension drawings 171 ...
Страница 172: ...172 ...
Страница 180: ...180 ...
Страница 198: ... Declaration of conformity 198 The Safe torque off function ...
Страница 206: ...Dimensions 206 BIO 01 I O extension module ...
Страница 212: ...Dimensions 3AXD50000031148 rev A 212 BREL 01 relay output extension module ...