Drive
9
2. An EMC plan for preventing disturbances is drawn up for the installation. A template
is available in
Technical guide No. 3 EMC compliant installation and configuration
for a power drive system
(3AFE61348280 (English)).
3. The motor and control cables are selected as specified in this manual. For the best
EMC performance, the EMC recommendations are obeyed.
4. The drive is installed according to the instructions given in this manual.
WARNING!
Do not install a drive with the internal EMC filter connected to an earthing system
that the EMC filter is not suitable for (for example, an IT system). The supply
network becomes connected to ground potential through the internal EMC filter
capacitors, which can cause danger or damage to the drive.
WARNING!
To prevent radio-frequency interference, do not use a category C4 drive on a
low-voltage public network that supplies domestic premises.
UL checklist
WARNING!
Operation of this drive requires detailed installation and operation instructions
provided in the hardware and software manuals. The manuals are provided in
electronic format in the drive package or on the Internet. Keep the manuals with
the drive at all times. Hard copies of the manuals can be ordered through the
manufacturer.
•
Make sure that the drive type designation label includes the applicable marking.
•
DANGER - Risk of electric shock.
After disconnecting the input power, always
wait for 5 minutes to let the intermediate circuit capacitors discharge before you
start working on the drive, motor or motor cable.
•
The drive is to be used in a heated, indoor controlled environment. The drive must
be installed in clean air according to the enclosure classification. Cooling air must
be clean, free from corrosive materials and electrically conductive dust.
•
The maximum surrounding air temperature is 50 °C (122 °F) at rated output current.
The output current is derated for 50 … 60 °C (122 … 140 °F) in drives with frame
size R1…R4.
•
The drive is suitable for use in a circuit capable of delivering not more than
100000 rms symmetrical amperes, 480 V maximum (480 V drive types) when
protected by the UL fuses given elsewhere in this chapter. The ampere rating is
based on tests done according to the appropriate UL standard.
152 Technical data
Содержание ACH480
Страница 1: ... ABB DRIVES FOR HVAC ACH480 drives Hardware manual ...
Страница 2: ......
Страница 4: ......
Страница 14: ...14 ...
Страница 22: ...22 ...
Страница 28: ...28 ...
Страница 38: ...38 ...
Страница 44: ...44 ...
Страница 60: ...60 ...
Страница 86: ...86 ...
Страница 110: ...110 ...
Страница 114: ...114 ...
Страница 122: ...122 ...
Страница 156: ...Frame R1 Frame R1 front side IP20 UL open type 156 Dimension drawings ...
Страница 157: ... Frame R1 bottom rear IP20 UL open type Dimension drawings 157 ...
Страница 158: ... Frame R1 front side UL Type 1 kit installed 158 Dimension drawings ...
Страница 159: ... Frame R1 bottom rear UL Type 1 kit installed Dimension drawings 159 ...
Страница 160: ...Frame R2 Frame R2 front side IP20 UL open type 160 Dimension drawings ...
Страница 161: ... Frame R2 bottom rear IP20 UL open type Dimension drawings 161 ...
Страница 162: ... Frame R2 front side UL Type 1 kit installed 162 Dimension drawings ...
Страница 163: ... Frame R2 bottom rear UL Type 1 kit installed Dimension drawings 163 ...
Страница 164: ...Frame R3 Frame R3 front side IP20 UL open type 164 Dimension drawings ...
Страница 165: ... Frame R3 bottom rear IP20 UL open type Dimension drawings 165 ...
Страница 166: ... Frame R3 front side UL Type 1 kit installed 166 Dimension drawings ...
Страница 167: ... Frame R3 bottom rear UL Type 1 kit installed Dimension drawings 167 ...
Страница 168: ...Frame R4 Frame R4 front side IP20 UL open type 168 Dimension drawings ...
Страница 169: ... Frame R4 bottom rear IP20 UL open type Dimension drawings 169 ...
Страница 170: ... Frame R4 front side UL Type 1 kit installed 170 Dimension drawings ...
Страница 171: ... Frame R4 bottom rear UL Type 1 kit installed Dimension drawings 171 ...
Страница 172: ...172 ...
Страница 180: ...180 ...
Страница 198: ... Declaration of conformity 198 The Safe torque off function ...
Страница 206: ...Dimensions 206 BIO 01 I O extension module ...
Страница 212: ...Dimensions 3AXD50000031148 rev A 212 BREL 01 relay output extension module ...