![ABB ACH480 Скачать руководство пользователя страница 100](http://html.mh-extra.com/html/abb/ach480/ach480_hardware-manual_2507100.webp)
■
Additional information on the control connections
Connecting EIA-485 fieldbus cable to the drive
Connect the cable to the EIA-485 terminal on the RIIO-01 I/O & EIA-485 module, which
is attached to the drive. The connection diagram is shown below.
The EIA-485 network uses shielded, twisted-pair cable with a characteristic impedance
of 100 … 130 ohm for data signaling. The distributed capacitance between conductors
is less than 100 pF per meter (30 pF per foot). Distributed capacitance between
conductors and shield is less than 200 pF per meter (60 pF per foot). Foil or braided
shields are acceptable.
...
ON
1
ON
1
ON
1
B
+
A
-
DG
ND
ON
1
ON
1
ON
1
B
+
A
-
DG
ND
ON
1
ON
1
ON
1
B
+
A
-
DG
ND
1
2
1
2
1
2
3
4
Drive
1
Termination switch. Termination must be on at both ends on the fieldbus. For the drive, the
termination switch position is ON.
2
Fieldbus controller
3
Fieldbus
4
100 Electrical installation – North America
Содержание ACH480
Страница 1: ... ABB DRIVES FOR HVAC ACH480 drives Hardware manual ...
Страница 2: ......
Страница 4: ......
Страница 14: ...14 ...
Страница 22: ...22 ...
Страница 28: ...28 ...
Страница 38: ...38 ...
Страница 44: ...44 ...
Страница 60: ...60 ...
Страница 86: ...86 ...
Страница 110: ...110 ...
Страница 114: ...114 ...
Страница 122: ...122 ...
Страница 156: ...Frame R1 Frame R1 front side IP20 UL open type 156 Dimension drawings ...
Страница 157: ... Frame R1 bottom rear IP20 UL open type Dimension drawings 157 ...
Страница 158: ... Frame R1 front side UL Type 1 kit installed 158 Dimension drawings ...
Страница 159: ... Frame R1 bottom rear UL Type 1 kit installed Dimension drawings 159 ...
Страница 160: ...Frame R2 Frame R2 front side IP20 UL open type 160 Dimension drawings ...
Страница 161: ... Frame R2 bottom rear IP20 UL open type Dimension drawings 161 ...
Страница 162: ... Frame R2 front side UL Type 1 kit installed 162 Dimension drawings ...
Страница 163: ... Frame R2 bottom rear UL Type 1 kit installed Dimension drawings 163 ...
Страница 164: ...Frame R3 Frame R3 front side IP20 UL open type 164 Dimension drawings ...
Страница 165: ... Frame R3 bottom rear IP20 UL open type Dimension drawings 165 ...
Страница 166: ... Frame R3 front side UL Type 1 kit installed 166 Dimension drawings ...
Страница 167: ... Frame R3 bottom rear UL Type 1 kit installed Dimension drawings 167 ...
Страница 168: ...Frame R4 Frame R4 front side IP20 UL open type 168 Dimension drawings ...
Страница 169: ... Frame R4 bottom rear IP20 UL open type Dimension drawings 169 ...
Страница 170: ... Frame R4 front side UL Type 1 kit installed 170 Dimension drawings ...
Страница 171: ... Frame R4 bottom rear UL Type 1 kit installed Dimension drawings 171 ...
Страница 172: ...172 ...
Страница 180: ...180 ...
Страница 198: ... Declaration of conformity 198 The Safe torque off function ...
Страница 206: ...Dimensions 206 BIO 01 I O extension module ...
Страница 212: ...Dimensions 3AXD50000031148 rev A 212 BREL 01 relay output extension module ...